When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the switch is held in the closed position by the hoistman. The overtravel by-pass switch shall return automatically to the open position when released by the hoistman.
Wire Ropes
053-2 Wyo. Code R. § 56.19018
50 FR 4054, 1/29/1985; 50 FR 20100, 5/14/1985
Authority: Sec. 101, Federal Mine Safety and Health Act of 1977, Pub. L. 91-173 as amended by Pub. L. 95-164, 91 Stat. 1291 ( 30 U.S.C. 811 ).