Wis. Admin. Code Department of Natural Resources NR 283.11

Current through August 26, 2024
Section NR 283.11 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available
(1) Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the effluent limitations representing the degree of effluent reduction attainable by the application of BPT, which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a point source times the following pollutant concentrations:

Table 1

Contact Cooling and Heating Water

Concentration used to calculate effluent limitations

Pollutant or pollutant property

Maximum for any 1 day (mg/l)

BOD5

26

Oil and grease

29

TSS

19

pH

(1)

1Within the range of 6.0 to 9.0 at all times.

(2) The department shall obtain the average process water usage flow rate for the contact cooling and heating water processes from the permittee.

Wis. Admin. Code Department of Natural Resources NR 283.11

Cr. Register, October, 1987, No. 382, eff. 11-1-87.