Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by application of BAT:
Table 14-4
Primary Antimony Sodium Antimonate Autoclave Wastewater
BAT Effluent Limitations | ||
Maximum for any 1 day | Maximum for monthly average | |
Pollutant or pollutant property | mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product | |
Antimony | 30.150 | 13.440 |
Arsenic | 21.720 | 9.687 |
Mercury | 2.344 | 0.937 |
Table 14-5
Primary Antimony Fouled Anolyte
BAT Effluent Limitations | ||
Maximum for any 1 day | Maximum for monthly average | |
Pollutant or pollutant property | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | |
Antimony | 30.150 | 13.440 |
Arsenic | 21.720 | 9.687 |
Mercury | 2.344 | 0.937 |
Table 14-6
Primary Antimony Cathode Antimony Wash Wate
BAT Effluent Limitations | ||
Maximum for any 1 day | Maximum for monthly average | |
Pollutant or pollutant property | mg/kg (pounds per million pounds) of antimony metal produced by electrowinning | |
Antimony | 60.310 | 26.870 |
Arsenic | 43.430 | 19.370 |
Mercury | 4.687 | 1.875 |
Wis. Admin. Code Department of Natural Resources NR 274.143