Wis. Admin. Code Department of Natural Resources NR 255.53

Current through October 28, 2024
Section NR 255.53 - New source performance standards
(1) The discharge of wastewater pollutants from any new source subject to this subchapter may not exceed the following standards:

Table 93

Lead Iodide Cathodes

NSPS

POLLUTANT OR

POLLUTANT PROPERTY

MAXIMUM FOR

ANY 1 DAY

MAXIMUM FOR

MONTHLY AVERAGE

Metric units -

mg/kg of lead

English units -

lb/million lbs of lead

Chromium

23.34

9.46

Lead

17.66

8.20

Iron

75.70

38.48

TSS

946.2

756.96

(1)

(1)

1Within the range of 7.5 to 10.0 at all times.

Table 94

Iron Disulfide Cathodes

NSPS

POLLUTANT OR

POLLUTANT PROPERTY

MAXIMUM FOR

ANY 1 DAY

MAXIMUM FOR

MONTHLY AVERAGE

Metric units -mg/kg of iron disulfide

English units -lb/million lbs of iron disulfide

Chromium

2.79

1.13

Lead

2.11

0.96

Iron

9.05

4.60

TSS

113.1

90.5

pH

(1)

(1)

1Within the range of 7.5 to 10.0 at all times.

Table 95

Miscellaneous Wastewater Streams

NSPS

POLLUTANT OR

POLLUTANT PROPERTY

MAXIMUM FOR

ANY 1 DAY

MAXIMUM FOR

MONTHLY AVERAGE

Metric units -

mg/kg of cells produced

English units -

lb/million lbs of cells produced

Chromium

0.039

0.016

Lead

0.030

0.014

Iron

0.129

0.066

TSS

1.62

1.30

(1)

(1)

1Within the range of 7.5 to 10.0 at all times.

Table 96

Air Scrubbers

NSPS

POLLUTANT OR

POLLUTANT PROPERTY

MAXIMUM FOR

ANY 1 DAY

MAXIMUM FOR

MONTHLY AVERAGE

Metric units -

mg/kg of cells produced

English units -

lb/million lbs of cells produced

TSS

434.0

207.0

pH

(1)

(1)

1Within the range of 7.5 to 10.0 at all times.

(2) There may be no discharge allowance for process wastewater pollutants from any battery manufacturing operation other than those battery manufacturing operations listed in tables 93 to 96.

Wis. Admin. Code Department of Natural Resources NR 255.53

Cr. Register, November, 1987, No. 383, eff. 12-1-87.