W. Va. Code R. agency 45, tit. 45, ser. 45-18, tbl. 45-18G

Current through Register Vol. XLI, No. 50, December 13, 2024
Table 45-18G

Operating limits for wet scrubbers

For these operating parameters

You shall establish these operating limits

And monitor using these minimum frequencies

Data measurement

Data recording

Averaging time

Charge rate

Maximum charge rate

Continuous

Every hour

Daily (batch units).

3-hour rolling (continuous and intermittent units)a

Pressure drop across the wet scrubber or amperage to wet scrubber

Minimum pressure drop or amperage

Continuous

Every 15 minutes

3-hour rollinga

Scrubber liquor flow rate

Minimum flow rate

Continuous

Every 15 minutes

3-hour rollinga

Scrubber liquor pH

Minimum pH

Continuous

Every 15 minutes

3-hour rollinga

a Calculated each hour as the average of the previous 3 operating hours.

W. Va. Code R. agency 45, tit. 45, ser. 45-18, tbl. 45-18G