W. Va. Code R. agency 45, tit. 45, ser. 45-18, tbl. 45-18F

Current through Register Vol. XLI, No. 50, December 13, 2024
Table 45-18F

Emission limits for existing commercial and industrial solid waste incinerators that apply before February 7, 2018b

Air pollutant

Emission limit a

Averaging time

Performance test methods

Cadmium

0.004 milligrams per dry standard cubic meter.

3-run average (1-hour minimum sample time per run).

Performance test (Method 29 of 40CFR 60, appendix A)

Carbon monoxide

157 parts per million by dry volume.

3-run average (1-hour minimum sample time per run).

Performance test (Method 10, 10A, or 10B, of 40CFR 60, appendix A)

Dioxins/furans (toxic equivalency basis)

0.41 nanograms per dry standard cubic meter.

3-run average (1-hour minimum sample time per run).

Performance test (Method 23 of 40CFR 60, appendix A)

Hydrogen chloride

62 parts per million by dry volume.

3-run average (For Method 26, collect a minimum volume of 120 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run).

Performance test (Method 26 or 26A of 40CFR 60, appendix A-8)

Lead

0.04 milligrams per dry standard cubic meter.

3-run average (1-hour minimum sample time per run).

Performance test (Method 29 of 40CFR 60, appendix A)

Mercury

0.47 milligrams per dry standard cubic meter.

3-run average (1-hour minimum sample time per run).

Performance test (Method 29 or 30B of 40CFR 60, appendix A-8) or ASTM D6784-02 (reapproved 2008)

Nitrogen oxides

388 parts per million by dry volume.

3-run average (1-hour minimum sample time per run).

Performance test (Method 7 or 7E of 40CFR 60, appendix A-4)

Opacity

10 percent

Three 1-hour blocks consisting of ten 6-minute average opacity values.

Performance test (Method 9 of 40CFR 60, appendix A-4)

Particulate matter

70 milligrams per dry standard

cubic meter.

3-run average (1-hour minimum sample time per run).

Performance test (Method 5 or 29 of 40CFR 60, appendix A)

Sulfur dioxide

20 parts per million by dry volume.

3-run average (1-hour minimum sample time per run).

Performance test (Method 6 or 6C of 40CFR 60, appendix A)

aAll emission limitations (except for opacity) are measured at 7 percent oxygen, dry basis at standard conditions.

bApplies only to incinerators subject to the CISWI standards through a state plan prior to June 4, 2010. The date specified in the state plan can be no later than 3 years after the effective date of approval of a revised state plan or February 7, 2018.

W. Va. Code R. agency 45, tit. 45, ser. 45-18, tbl. 45-18F