Current through Register Vol. 41, No. 8, December 2, 2024
Section 2VAC5-585-1310 - Vending machines, automatic shutoffA. A machine vending time/temperature control for safety food shall have an automatic control that prevents the machine from vending food: 1. If there is a power failure, mechanical failure, or other condition that results in an internal machine temperature that cannot maintain food temperatures as specified under Part III (2VAC5-585-260 et seq.) of this chapter;P and2. If a condition specified under subdivision 1 of this subsection occurs, until the machine is serviced and restocked with food that has been maintained at temperatures specified under Part III (2VAC5-585-260 et seq.) of this chapter.PB. When the automatic shutoff within a machine vending time/temperature control for safety food is activated: 1. In a refrigerated vending machine, the ambient temperature may not exceed 41°F (5°C) for more than 30 minutes immediately after the machine is filled, serviced, or restocked;P or2. In a hot holding vending machine, the ambient temperature may not be less than 135°F (57°C) for more than 120 minutes immediately after the machine is filled, serviced, or restocked.P2 Va. Admin. Code § 5-585-1310
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; amended, Virginia Register Volume 26, Issue 7, eff. January 1, 2010; Amended, Virginia Register Volume 32, Issue 22, eff. 7/12/2016; Amended, Virginia Register Volume 37, Issue 19, eff. 6/24/2021.Statutory Authority: § 3.2-5121 of the Code of Virginia.