Current through Bulletin 2024-24, December 15, 2024
Section R392-302-38 - Special Purpose Pools: Wading Pools(1) The manager shall consult with the local health officer before opening a wading pool.(2) The manager shall ensure that each wading pool:(a) meets any applicable requirement of this rule in addition to this section;(b) is separate from other pools;(c) does not share common circulation, filtration, chemical treatment systems, or a wall with other pools;(d) does not exceed a maximum water depth of two feet;(e) has a minimum of one turnover per hour as described in Table 1;(f) has a minimum of two equally spaced inlets around the perimeter of the wading pool, if the wading pool has wall inlets;(g) with a perimeter that exceeds 20 feet, has wall inlets that are spaced at a minimum of one in each 20 feet or fraction thereof; and(h) has a drain to waste for wastewater disposal as described in Section R392-302-7 through a quick opening valve to facilitate emptying the wading pool for a fecal release or other contamination.(3) The local health officer may allow the deck of a wading pool to be included as part of adjacent pool decks.Utah Admin. Code R392-302-38
Adopted by Utah State Bulletin Number 2018-12, effective 5/24/2018Amended by Utah State Bulletin Number 2020-05, effective 2/26/2020Amended by Utah State Bulletin Number 2020-16, effective 8/10/2020Adopted by Utah State Bulletin Number 2023-17, effective 8/21/2023