S.D. Admin. R. 20:74:06:14

Current through Register Vol. 51, page 67, December 16, 2024
Section 20:74:06:14 - Stove and fireplace components for inspection - Exclusions

A home inspector shall inspect stove and fireplace components as follows:

(1) The inspector shall observe and report on the following:
(a) Fireplaces - fuel type, location, abnormal cracks or openings in visible portion of firebox, operation of damper, if accessible, existence of flue liner, type of venting for gas fireplace, presence and operation of blower;
(b) Stoves - fuel types, location, distance from combustible surfaces/floor protection, connection to flue, existence of flue liner, operation of damper, if accessible, presence and operation of blower;
(2) The inspector is not required to:
(a) Report on interior condition of liner;
(b) Perform a smoke test;
(c) Test blower if on a thermostat;
(d) Operate gas appliances if gas is shut off;
(e) Operate remote controls;
(f) Determine adequacy of flue draft; or
(g) Report on compliance with current regulatory codes.

S.D. Admin. R. 20:74:06:14

28 SDR 28, effective 9/2/2001.

General Authority:36-21C-6(2).

Law Implemented:36-21C-6(2).