Section 20:74:06:13 - Central heating components for inspection - Exclusions

A home inspector shall inspect central heating components as follows:

(1) The inspector shall observe and report on the following:
(a) Type of system (i.e., forced air, hot water baseboard, ceiling radiant, heat pump, etc.)
(b) Fuel type (i.e., electric, natural gas, propane, oil, coal, wood, or other);
(c) Manufacturer;
d) Estimated age (or age from data plate);
(e) Functional operation from thermostat;
(f) General condition of system;
(g) Air flow at registers, if applicable - verify;
(h) Positive pitch of flue pipes - verify;
(i) General appearance of humidifiers;
(j) Supplemental heat systems; and
(k) Gas control valves and shutoff valves - check for leak;
(2) The inspector is not required to:
(a) Verify or operate safety control devices;
(b) Operate heat pumps if outside temperature is above 75 degrees Fahrenheit; or
(c) Remove panels other than those designed to be removed for routine homeowner maintenance.