510 R.I. Code R. 510-RICR-00-00-2.24

Current through December 3, 2024
Section 510-RICR-00-00-2.24 - Chapter 30
P3003.9.2 Solvent Cementing- Delete Exception
P3008.1 Delete section P3008.1 and substitute the following
P3008.1 Mandatory installation of check valves.

All new residential construction that will connect to a sanitary sewer system and any residential construction where the existing sewer connection will be substantially altered shall have a check valve installed that is automatically activated, on the main building sewer line for purposes of protecting residents from the possible backflow of, and exposure to, untreated sewage.

510 R.I. Code R. 510-RICR-00-00-2.24

Amended effective8/1/2019
Amended effective 2/1/2022