Section 3701:1-52-09 - Shielding
(A) The radiation dose rate in areas that are normally occupied during operation of a panoramic irradiator may not exceed 0.02 millisievert (two millirem) per hour at any location thirty centimeters or more from the wall of the room when the sources are exposed. The dose rate must be averaged over an area not to exceed one hundred square centimeters having no linear dimension greater than twenty centimeters. Areas where the radiation dose rate exceeds 0.02 millisievert (two millirem) per hour must be locked, roped off, or posted.
(B) The radiation dose rate at thirty centimeters over the edge of the containment pool of a pool irradiator may not exceed 0.02 millisievert (two millirem) per hour when the sources are in the fully shielded position.
(C) The radiation dose rate at one meter from the shield of a dry-source-storage panoramic irradiator when the source is shielded may not exceed 0.02 millisievert (two millirem) per hour and at five centimeters from the shield may not exceed 0.2 millisievert (twenty millirem) per hour.

Ohio Admin. Code 3701:1-52-09

Five Year Review (FYR) Dates: 4/19/2022 and 04/19/2027
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 10/08/2007
Five Year Review (FYR) Dates: 10/25/2016 and 10/15/2021
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 10/08/07