Current through Register No. 50, December 12, 2024
Section Env-A 808.13 - Quarterly Emission Reports(a) Within 30 days after the end of each calendar quarter, an owner or operator of a source with a gaseous or opacity CEM system shall submit an emission report to the department which contains the following: (1) The information required to be submitted by 40 CFR 60, 40 CFR 63, or 40 CFR 75, relative to installation, calibration, operation and maintenance of a certified gaseous or opacity CEM system;(2) All information included in the emission report shall be clearly indicated, labeled, and formatted such that compliance with all emissions standards to which the source is subject, can be determined and any periods of excess emissions, substitution of missing or invalid CEM data, CEM calibration, CEM maintenance, or startup, shutdown, or malfunction can be easily identified;(3) The daily averages of gaseous and opacity CEM measurements and calculated emission rates in the units of the emissions standards;(4) For those sources subject to any emission standards that are averaged or totaled over a period of less than 24 hours, other than opacity standards that are averaged over less than a 24-hour period, the CEM data averaged and reported on the basis of the emission standard;(5) For those sources subject to any emission standard that is a rolling average of more than one operating day, the rolling average emission rate reported for each day during the reporting period;(6) Excess emission data recorded by the CEM system, including: a. The date and time of the beginning and ending of each period of excess emission;b. The actual emissions measured by the CEM system during the excess emission;c. The total amount of emissions above the emissions limit, or percent above the emissions limit, during the period of excess emissions;d. The specific cause of the excess emission; ande. The corrective action taken;(7) If no excess emissions have occurred, a statement to that effect;(8) A statement as to whether the CEM system was inoperative, repaired, or adjusted during the reporting period;(9) If the CEM system was inoperative, repaired, or adjusted during the reporting period, the following information: a. The date and time of the beginning and ending of each period when the CEM was inoperative;b. The reason why the CEM was not operating; andc. The corrective action taken;(10) For all "out of control periods" as defined in Env-A 808.01(j), 40 CFR 60, Appendix F, and any applicable federal requirement, the following information: a. The date and time of the beginning and end of the out of control period;b. The reason for the out of control period; andc. The corrective action taken;(11) The date and time of the beginning and end of each period when the source of emissions which the CEM system is monitoring was not operating;(12) The span value, as defined in Env-A 101, and units of measurement for each analyzer in the CEM system;(13) When calibration gas is used, the following information: a. The calibration gas concentration;b. If a gas bottle was changed during the quarter: 1. The date of the calibration gas bottle change;2. The gas bottle concentration before the change; and3. The gas bottle concentration after the change; andc. The expiration date for all calibration gas bottles used; and(14) The percent data availability calculated in accordance with Env-A 808.11 for each gaseous, opacity, and flow rate monitor in the CEM system.(b) If the source submits emissions data calculated on a basis of less than a 24-hour period, as is required by (a)(4) above, then the emissions data shall be submitted to the department in an electronic format.(c) The quarterly report submittal shall be consistent with the information previously submitted in the CEM System Monitoring Plan and approved by the department.N.H. Admin. Code § Env-A 808.13
#7788, eff 10-31-02; ss by #9802, eff 10-31-10
Amended by Volume XXXIX Number 19, Filed May 9, 2019, Proposed by #12762, Effective 5/1/2019, Expires 5/1/2029.