N.H. Admin. Code § Env-A 1303.07

Current through Register No. 50, December 12, 2024
Section Env-A 1303.07 - RACT Requirements: Dry-Bottom Utility Boilers Firing Coal and/or Oil

For dry-bottom utility boilers that fire, or that are capable of firing, coal or oil, or any combination thereof, the NOx RACT requirements shall be as follows:

(a) For tangential-fired boilers, an emission limit of 0.38 lb. per million Btu, based on a 24-hour calendar day average;
(b) For face-fired boilers, an emission limit of 0.50 lb. per million Btu, based on a 24-hour calendar day average; and
(c) For stoker-fired boilers, an emission limit of 0.30 lb. per million Btu, based on a 24-hour calendar day average.

N.H. Admin. Code § Env-A 1303.07

(See Revision Note at chapter heading for Env-A 1300) #9803, eff 10-31-10

Amended by Volume XXXVIII Number 32, Filed August 9, 2018, Proposed by #12584, Effective 8/15/2018, Expires 8/15/2028.