Section 096-526-4 - Definitions

The following terms, as used in this Chapter, have the following meanings, unless the context indicates otherwise. Terms not otherwise defined have the meaning given by Chapter 520, Title 38 M.R.S. § 361-A, or the Federal Clean Water Act. When a defined term appears in a definition, the defined term is sometimes italicized as an aid to readers. [See 40 CFR § 125.83 and 125.92]

A.Actual intake flow (AIF) means the average volume of water withdrawn on an annual basis by the cooling water intake structures over the previous five years. Actual intake flow is measured at a location within the cooling water intake structure that the Department deems appropriate. The calculation of actual intake flow includes days of zero flow. AIF does not include flows associated with emergency and fire suppression capacity.
B.All life stages of fish and shellfish means eggs, larvae, juveniles, and adults. It does not include members of the infraclass Cirripedia in the subphylum Crustacea (barnacles), green mussels (Perna viridis), or zebra mussels (Dreissena polymorpha). The Department may determine that all life stages of fish and shellfish does not include other specified nuisance species.
C.Annual mean flow means the average of daily flows over a calendar year. Historical data (up to 10 years) must be used where available.
D.Closed-cycle recirculating system means a system designed and properly operated using minimized make-up and blowdown flows withdrawn from a water of the State to support contact or non-contact cooling uses within a facility, or a system designed to include certain impoundments. A closed-cycle recirculating system passes cooling water through a heat exchange system such as a condenser and other components of the cooling system and reuses the water for cooling multiple times.
(1)Closed-cycle recirculating system includes wet, dry, or hybrid cooling towers, a system of impoundments that are not waters of the State, or any combination thereof. A properly operated and maintained closed-cycle recirculating system withdraws new source water (make-up water) only to replenish losses that have occurred due to blowdown, drift, and evaporation. If waters of the State are withdrawn for purposes of replenishing losses to a closed-cycle recirculating system other than those due to blowdown, drift, and evaporation from the cooling system, the Department may determine a cooling system is a closed-cycle recirculating system if the facility demonstrates to the satisfaction of the Department that make-up water withdrawals attributed specifically to the cooling portion of the cooling system have been minimized.
(2)Closed-cycle recirculating system also includes a system with impoundments of waters of the State where the impoundment was created for the purpose of serving as part of the cooling water system as documented in the project purpose statement for any required Clean Water Act section 404 permit obtained to construct the impoundment. In the case of an impoundment whose construction pre-dated the CWA requirement to obtain a section 404 permit, documentation of the project's purpose must be demonstrated to the satisfaction of the Department. This documentation could be some other license or permit obtained to lawfully construct the impoundment for the purposes of a cooling water system, or other such evidence as the Department finds necessary. For impoundments constructed in uplands or not in waters of the State, no documentation of a section 404 or other permit is required. If waters of the State are withdrawn for purposes of replenishing losses to a closed-cycle recirculating system other than those due to blowdown, drift, and evaporation from the cooling system, the Department may determine a cooling system is a closed-cycle recirculating system if the facility demonstrates to the satisfaction of the Department that make-up water withdrawals attributed specifically to the cooling portion of the cooling system have been minimized.
E.Contact cooling water means water used for cooling that comes into direct contact with any raw material, product, or byproduct. Examples of contact cooling water may include but are not limited to quench water at facilities, cooling water in a cracking unit, and cooling water directly added to food and agricultural products processing.
F.Cooling water means water used for contact or non-contact cooling, including water used for equipment cooling, evaporative cooling tower makeup, and dilution of effluent heat content. The intended use of the cooling water is to absorb waste heat rejected from the process or processes used, or from auxiliary operations on the facility's premises. Cooling water obtained from a public water system, reclaimed water from wastewater treatment facilities or desalination plants, treated effluent from a manufacturing facility, or cooling water that is used in a manufacturing process either before or after it is used for cooling as process water, is not considered cooling water for the purposes of calculating the percentage of a facility's intake flow that is used for cooling purposes in section 5.D or 12.A(3).
G.Cooling water intake structure means the total physical structure and any associated constructed waterways used to withdraw cooling water from waters of the State. The cooling water intake structure extends from the point at which water is first withdrawn from surface waters of the State up to, and including, the intake pumps, if present.
H.Design intake flow (DIF) means the value assigned during the cooling water intake structure design to the maximum instantaneous rate of flow of water the cooling water intake system is capable of withdrawing from a source water body. The facility's DIF may be adjusted to reflect permanent changes to the maximum capabilities of the cooling water intake system to withdraw cooling water, including pumps permanently removed from service, flow limit devices, and physical limitations of the piping. DIF does not include values associated with emergency and fire suppression capacity or redundant pumps (i.e., back-up pumps).
I.Design intake velocity means the value assigned (during the design of a cooling water intake structure) to the average speed at which intake water passes through the open area of the intake screen (or other device) against which organisms might be impinged or through which they might be entrained.
J.Entrainment means any life stages of fish and shellfish in the intake water flow entering and passing through a cooling water intake structure and into a cooling water system, including a condenser or heat exchanger. Entrainable organisms include any organisms potentially subject to entrainment. For purposes of this Chapter, entrainment excludes those organisms that are collected or retained by a sieve with maximum opening dimension of 0.56 inches. Examples of sieves meeting this definition include but are not limited to a 3/8-inch square mesh, or a 1/2 by 1/4-inch mesh. A facility must use the same mesh size when counting entrainment as is used when counting impingement.
K.Entrainment mortality means death as a result of entrainment through the cooling water intake structure, or death as a result of exclusion from the cooling water intake structure by fine mesh screens or other protective devices intended to prevent the passage of entrainable organisms through the cooling water intake structure.
L.Entrapment means the condition where impingeable fish and shellfish lack the means to escape the cooling water intake. Entrapment includes but is not limited to: Organisms caught in the bucket of a traveling screen and unable to reach a fish return; organisms caught in the forebay of a cooling water intake system without any means of being returned to the source water body without experiencing mortality; or cooling water intake systems where the velocities in the intake pipes or in any channels leading to the forebay prevent organisms from being able to return to the source water body through the intake pipe or channel.
M.Estuary means a semi-enclosed body of water that has a free connection with open seas and within which the seawater is measurably diluted with fresh water derived from land drainage. The salinity of an estuary exceeds 0.5 parts per thousand (by mass) but is typically less than 30 parts per thousand (by mass).
N.Existing facility means any facility that commenced construction as described in 40 CFR § 122.29(b)(4) on or before January 17, 2002, and any modification of, or any addition of a unit at such a facility. A facility built adjacent to another facility would be a new facility while the original facility would remain as an existing facility for purposes of this Chapter. A facility cannot both be an existing facility and a new facility as defined in this Chapter.
O.Flow reduction means any modification to a cooling water intake structure or its operation that serves to reduce the volume of cooling water withdrawn. Examples include, but are not limited to, variable speed pumps, seasonal flow reductions, wet cooling towers, dry cooling towers, hybrid cooling towers, unit closures, or substitution for withdrawals by reuse of effluent from a nearby facility.
P.Fragile species means those species of fish and shellfish that are least likely to survive any form of impingement. For purposes of this Chapter, fragile species are defined as those with an impingement survival rate of less than 30 percent, including but not limited to alewife, American shad, Atlantic herring, Atlantic long-finned squid, Atlantic menhaden, bay anchovy, blueback herring, bluefish, butterfish, gizzard shad, gray snapper, hickory shad, menhaden, rainbow smelt, round herring, and silver anchovy.
Q.Freshwater river or stream means a lotic (free flowing) system that does not receive significant inflows of water from oceans or bays due to tidal action. For the purposes of this Chapter, a flow-through reservoir with a retention time of seven days or less will be considered a freshwater river or stream.
R.Hydraulic zone of influence means that portion of the source water body hydraulically affected by the cooling water intake structure withdrawal of water.
S.Impingement means the entrapment of any life stages of fish and shellfish on the outer part of an intake structure or against a screening device during periods of intake water withdrawal. For purposes of this Chapter, impingement includes those organisms collected or retained on a sieve with maximum distance in the opening of 0.56 inches and excludes those organisms that pass through the sieve. Examples of sieves meeting this definition include but are not limited to a 3/8-inch square mesh, or a 1/2 by 1/4-inch mesh. This definition is intended to prevent the conversion of entrainable organisms to counts of impingement or impingement mortality. The Owner or Operator of a facility must use a sieve with the same mesh size when counting entrainment as is used when counting impingement.
T.Impingement mortality means death as a result of impingement. Impingement mortality also includes organisms removed from their natural ecosystem and lacking the ability to escape the cooling water intake system, and thus subject to inevitable mortality.
U.Independent supplier means an entity, other than the regulated facility, that owns and operates its own cooling water intake structure and directly withdraws water from waters of the State. The supplier provides the cooling water to other facilities for their use but may itself also use a portion of the water. An entity that provides potable water to residential populations (e.g., public water system) is not a supplier for purposes of this Chapter.
V.Lake or reservoir means any inland body of open water with some minimum surface area free of rooted vegetation and with an average hydraulic retention time of more than seven days. Lakes or reservoirs might be natural water bodies or impounded streams, usually fresh, surrounded by land or by land and a man-made retainer (e.g., a dam). Lakes or reservoirs might be fed by rivers, streams, springs, and/or local precipitation. Flow-through reservoirs with an average hydraulic retention time of seven days or less should be considered a freshwater river or stream.
W.Latent mortality means the delayed mortality of organisms that were initially alive upon being impinged or entrained but that do not survive the delayed effects of impingement and entrainment during an extended holding period. Delayed effects of impingement and entrainment include but are not limited to temperature change, physical stresses, and chemical stresses.
X.Maximize means to increase to the greatest amount, extent, or degree reasonably possible.
Y.Minimize means to reduce to the smallest amount, extent, or degree reasonably possible.
Z.Modified traveling screen means a traveling water screen that incorporates measures protective of fish and shellfish, including but not limited to: screens with collection buckets or equivalent mechanisms designed to minimize turbulence to aquatic life; addition of a guard rail or barrier to prevent loss of fish from the collection system; replacement of screen panel materials with smooth woven mesh, drilled mesh, molded mesh, or similar materials that protect fish from descaling and other abrasive injury; continuous or near-continuous rotation of screens and operation of fish collection equipment to ensure any impinged organisms are recovered as soon as practical; a low pressure wash or gentle vacuum to remove fish prior to any high pressure spray to remove debris from the screens; and a fish handling and return system with sufficient water flow to return the fish directly to the source water in a manner that does not promote predation or re-impingement of the fish, or require a large vertical drop. The Department may approve of fish being returned to water sources other than the original source water, taking into account any recommendations from the Services with respect to endangered or threatened species. Examples of modified traveling screens include but are not limited to: Modified Ristroph screens with a fish handling and return system, dual flow screens with smooth mesh, and rotary screens with fish returns or vacuum returns.
AA.Moribund means dying; close to death.
BB.Natural thermal stratification means the naturally occurring division of a water body into horizontal layers of differing densities as a result of variations in temperature at different depths.
CC.New facility means any building, structure, facility, or installation that meets the definition of a "new source" or "new discharger" in Chapter 520 and 40 CFR § 122.29(b)(1), (2), and (4) and is a greenfield or stand-alone facility; commences construction after January 17, 2002; and uses either a newly constructed cooling water intake structure, or an existing cooling water intake structure whose design capacity is increased to accommodate the intake of additional cooling water. New facilities include only "greenfield" and "stand-alone" facilities. A greenfield facility is a facility that is constructed at a site at which no other source is located, or that totally replaces the process or production equipment at an existing facility (see 40 CFR § 122.29(b)(1)(i) and (ii)). A stand-alone facility is a new, separate facility that is constructed on property where an existing facility is located and whose processes are substantially independent of the existing facility at the same site (see 40 CFR § § 122.29(b)(1)(iii)). New facility does not include new units that are added to a facility for purposes of the same general industrial operation (for example, a new peaking unit at an electrical generating station).
(1) Examples of "new facilities" include, but are not limited to, the following scenarios:
(i) A new facility is constructed on a site that has never been used for industrial or commercial activity. It has a new cooling water intake structure for its own use.
(ii) A facility is demolished and another facility is constructed in its place. The newly constructed facility uses the original facility's cooling water intake structure but modifies it to increase the design capacity to accommodate the intake of additional cooling water.
(iii) A facility is constructed on the same property as an existing facility but is a separate and independent industrial operation. The cooling water intake structure used by the original facility is modified by constructing a new intake bay for the use of the newly constructed facility or is otherwise modified to increase the intake capacity for the new facility.
(2) Examples of facilities that would not be considered a "new facility" include, but are not limited to, the following scenarios:
(i) A facility in commercial or industrial operation is modified and either continues to use its original cooling water intake structure or uses a new or modified cooling water intake structure.
(ii) A facility has an existing intake structure. Another facility (a separate and independent industrial operation) is constructed on the same property and connects to the facility's cooling water intake structure behind the intake pumps, and the design capacity of the cooling water intake structure has not been increased. This facility would not be considered a "new facility" even if routine maintenance or repairs that do not increase the design capacity were performed on the intake structure.
DD.New unit means a new "stand-alone" unit at an existing facility where construction of the new unit begins after October 14, 2014, and that does not otherwise meet the definition of a new facility in this Chapter or is not otherwise already subject to this Chapter. A stand-alone unit is a separate unit that is added to a facility for either the same general industrial operation or another purpose. A new unit may have its own dedicated cooling water intake structure, or the new unit may use an existing or modified cooling water intake structure.
EE.Ocean means marine open coastal waters with a salinity greater than or equal to 30 parts per thousand (by mass).
FF.Offshore velocity cap means a velocity cap located a minimum of 800 feet from the shoreline. A velocity cap is an open intake designed to change the direction of water withdrawal from vertical to horizontal, thereby creating horizontal velocity patterns that result in avoidance of the intake by fish and other aquatic organisms. For purposes of this Chapter, the velocity cap must use bar screens or otherwise exclude marine mammals, sea turtles, and other large aquatic organisms.
GG.Operational measure means a modification to any operation that serves to minimize impact to all life stages of fish and shellfish from the cooling water intake structure. Examples of operational measures include, but are not limited to, more frequent rotation of traveling screens, use of a low-pressure wash to remove fish prior to any high-pressure spray to remove debris, maintaining adequate volume of water in a fish return, and debris minimization measures such as air sparging of intake screens and/or other measures taken to maintain the design intake velocity.
HH.Social benefits means the increase in social welfare that results from taking an action. Social benefits include private benefits and those benefits not taken into consideration by private decision makers in the actions they choose to take, including effects occurring in the future. Benefits valuation involves measuring the physical and biological effects on the environment from the actions taken. Benefits are generally treated one or more of three ways: a narrative containing a qualitative discussion of environmental effects, a quantified analysis expressed in physical or biological units, and a monetized benefits analysis in which dollar values are applied to quantified physical or biological units. The dollar values in a social benefits analysis are based on the principle of willingness-to-pay, which captures monetary benefits by measuring what individuals are willing to forgo in order to enjoy a particular benefit. Willingness-to-pay for nonuse values can be measured using benefits transfer or a stated preference survey.
II.Social costs means costs estimated from the viewpoint of society, rather than individual stakeholders. Social cost represents the total burden imposed on the economy; it is the sum of all opportunity costs incurred associated with taking actions. These opportunity costs consist of the value lost to society of all the goods and services that will not be produced and consumed as a facility complies with permit requirements, and society reallocates resources away from other production activities and towards minimizing adverse environmental impacts.
JJ.Source water means the water body (waters of the State) from which the cooling water is withdrawn.
KK.Thermocline means the middle layer of a thermally stratified lake or reservoir. In this layer, there is a rapid decrease in temperatures.
LL.Tidal excursion means the horizontal distance along the estuary or tidal river that a particle moves during one tidal cycle of ebb and flow.
MM.Tidal river means the most seaward reach of a river or stream where the salinity is typically less than or equal to 0.5 parts per thousand (by mass) at a time of annual low flow and whose surface elevation responds to the effects of coastal lunar tides.

06-096 C.M.R. ch. 526, § 4