C.M.R. 01, 001, ch. 346, § 001-346-9, subsec. 001-346-9-12

Current through 2024-51, December 18, 2024
Subsection 001-346-9-12 - Light Intensity
A. The light intensity must be:
1. At least 10 foot candles at a distance of 30 inches above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning;
2. At least 20 foot candles:
a. At a surface where food is provided for consumer produce self-service such as buffets and salad bars or where fresh or packaged foods are sold or offered for consumption;
b. Inside equipment such as reach-in and under-counter refrigerators;
3. At a minimum of 30 foot candles at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor; and
4. A minimum of 50-foot candles of shadow free lighting at the inspection surfaces of the head, viscera, and carcass.
5. A minimum of 200-foot candles of shadow free lighting at the inspection surface for Poultry.

C.M.R. 01, 001, ch. 346, § 001-346-9, subsec. 001-346-9-12