Authority: IC 15-16-2-44
Affected: IC 15-16-2
Sec. 2.
Unless there is a gradient barrier and a minimum setback of ten (10) feet or a filter strip with a minimum width of fifty (50) feet located between the application site and any of the known features in Table 1, a person shall apply unmanipulated organic fertilizer according to the setback distances in the following table:
Table 1 - Unmanipulated Organic Fertilizer Application Setback Distances (in feet)
Table 1 - Unmanipulated Organic Fertilizer Application Setback Distances (in feet) | ||||
Known Feature | Liquid - Injection or Single Pass Incorporation (liquid/solid) | Liquid - Incorporation; Surface Application (solid or compost); or Surface Application to Pasture | Liquid - Surface Application | |
[LESS THAN] 6% Slope; or Residue Cover | [GREATER THAN] 6% Slope | |||
Public Water Supply Wells and Surface Intake | 500 | 500 | 500 | 500 |
Surface Waters | 25 | 50 | 100 | 200 |
Sinkholes | 25 | 50 | 100 | 200 |
Water Wells | 50 | 50 | 100 | 200 |
Drainage Inlets | 5 | 50 | 100 | 200 |
Property Lines and Public Roads | 0 | 10 | 50 | 50 |
355 IAC 8-3-2