Authority: IC 13-14-8; IC 13-17-3-4; IC 13-17-3-11
Affected: IC 13-15; IC 13-17
Sec. 10.
ArcelorMittal USA LLC (Indiana Harbor West), Source Identification Number 00318, shall comply with the sulfur dioxide emission limits in pounds per million British thermal units (MMBtu), pounds per hour, and other requirements as follows:
Emissions Unit Description | Emission Limit lbs/MMBtu | Emission Limit lbs/hour |
(1) Utility Boilers 5, 6, 7, and 8: | 0.594 each | 1456.5 total |
(A) Total actual heat input from fuel oil usage at all boilers combined shall must not exceed two thousand four hundred fifty-two (2,452) MMBtu per hour. | ||
(B) Boilers shall must be fired on fuel oil, blast furnace gas, and natural gas only. | ||
(C) Fuel oil burned shall must not exceed one and three-tenths percent (1.3%) sulfur and one and thirty-five hundredths (1.35) pounds per MMBtu. | ||
(D) Utility Boilers 5, 6, 7, and 8 in combination with the Ironside Energy, LLC Utility Boiler No. 9 are limited to an annual operating limit of five thousand eight hundred seventy-one and sixty-one hundredths (5,871.61) tons per year. | ||
(2) Blast Furnace Stoves: | ||
(A) No. 3 Blast Furnace Stove | 0.290 | 127.89 |
(B) No. 4 Blast Furnace Stove | 0.290 | 140.94 |
(3) Reladling and Desulfurization Baghouse | 0.057 pounds per ton feed material | 30.40 |
(4) Number 4 Blast Furnace EC Baghouse | 0.18 pounds per ton feed material | 69.9 |
326 IAC 7-4.1-10