3 Colo. Code Regs. § 709-1.22

Current through Register Vol. 47, No. 22, November 25, 2024
Section 3 CCR 709-1.22 - Use of Lasers

This Rule is promulgated pursuant to sections 12-20-204, 12-220-105(3), 12-220-106(1)(a), and 12-220-106(1)(a)(I), C.R.S.

A. The requirements in this Rule do not apply to use of non-adjustable laser units for purposes of diagnosis and curing.
B. A dentist may use a laser capable of the removal of hard and soft tissue in the treatment of a dental patient.
C. Laser use by a dental therapist or a dental hygienist can only be performed on soft tissue under the indirect or direct supervision of a dentist and must be within the dental therapy or the dental hygiene scope of practice.
D. A licensee who is a laser user or supervises a laser user must first successfully complete training that covers a minimum of eight hours of laser physics, safety, and appropriate use, to include a hands on component, prior to utilizing the laser.
1. Training must be obtained through a course provided or recognized by any of the following organizations (or a successor organization):
a. A Commission on Dental Accreditation (CODA) approved institution;
b. The American Dental Association (ADA) Continuing Education Recognition Program (CERP);
c. The Academy of General Dentistry (AGD) Program Approval for Continuing Education (PACE); or
d. The American Medical Association (AMA).
2. A licensee utilizing a laser, other than what is described in section (A) of this Rule, must maintain evidence of training as required in section (D)(1) of this Rule. Upon request of the Board, the licensee must submit evidence of such training.
3. A licensee must also complete live and interactive training that addresses operation of the specific laser(s) utilized in the practice.
E. All lasers must be used in accordance with accepted safety guidelines.
F. When utilizing a laser pursuant to this Rule, at a minimum, the following must be documented in the patient's record:
1. Type of laser, including wavelength;
2. Settings used (pulse or continuous wave, power setting);
3. Size of fiber, tip, or aperture of tip; and
4. Procedure performed with details to include hard and/or soft tissue removal.

3 CCR 709-1.22

Adopted January 22, 2015, Effective March 30, 2015; Amended April 30, 2015, Effective June 30, 2015; Amended April 28, 2016, Effective June 30, 2016; Amended May 3, 2018, Effective July 3, 2018; Amended November 5, 2020; Effective December 30, 2020; Amended November 3, 2022; Effective December 30, 2022
38 CR 04, February 25, 2015, effective 3/30/2015
38 CR 11, June 10, 2015, effective 6/30/2015
39 CR 04, February 25, 2016, effective 3/16/2016
39 CR 10, May 25, 2016, effective 6/30/2016
39 CR 16, August 25, 2016, effective 9/14/2016
41 CR 04, February 25, 2018, effective 3/17/2018
41 CR 11, June 10, 2018, effective 7/3/2018
41 CR 14, July 25, 2018, effective 8/14/2018
42 CR 11, June 10, 2019, effective 6/30/2019
42 CR 23, December 10, 2019, effective 1/1/2020
44 CR 11, June 10, 2021, effective 6/30/2021
44 CR 16, August 25, 2021, effective 9/14/2021
44 CR 23, December 10, 2021, effective 12/30/2021
45 CR 21, November 10, 2022, effective 10/4/2022
45 CR 23, December 10, 2022, effective 12/10/2022
45 CR 23, December 10, 2022, effective 12/30/2022