Table 1 to Paragraph (a)(1)
Category | Equipment subcategory | Required represented values |
Single-Package Unit | Single-Package Air Conditioner (AC) (including space-constrained) | Every individual model distributed in commerce. |
Single-Package Heat Pump (HP) (including space-constrained) | ||
Outdoor Unit and Indoor Unit (Distributed in Commerce by Outdoor Unit Manufacturer (OUM)) | Single-Split-System AC with Single-Stage or Two-Stage Compressor (including Space-Constrained and Small-Duct, High Velocity Systems (SDHV)) | Every individual combination distributed in commerce. Each model of outdoor unit must include a represented value for at least one coil-only individual combination that is distributed in commerce and which is representative of the least efficient combination distributed in commerce with that particular model of outdoor unit. For that particular model of outdoor unit, additional represented values for coil-only and blower-coil individual combinations are allowed, if distributed in commerce. |
Single-Split System AC with Other Than Single-Stage or Two-Stage Compressor (including Space-Constrained and SDHV) | Every individual combination distributed in commerce, including all coil-only and blower-coil combinations. | |
Single-Split-System HP (including Space-Constrained and SDHV) | Every individual combination distributed in commerce. | |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-non-SDHV (including Space-Constrained) | For each model of outdoor unit, at a minimum, a non-ducted "tested combination." For any model of outdoor unit also sold with models of ducted indoor units, a ducted "tested combination." When determining represented values on or after January 1, 2023, the ducted "tested combination" must comprise the highest static variety of ducted indoor unit distributed in commerce (i.e., conventional, mid-static, or low-static). Additional representations are allowed, as described in paragraphs (c)(3)(i) and (ii) of this section, respectively. | |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-SDHV | For each model of outdoor unit, an SDHV "tested combination." Additional representations are allowed, as described in paragraph (c)(3)(iii) of this section. | |
Indoor Unit Only Distributed in Commerce by Independent Coil Manufacturer (ICM) | Single-Split-System Air Conditioner (including Space-Constrained and SDHV) Single-Split-System Heat Pump (including Space-Constrained and SDHV) | Every individual combination distributed in commerce. |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-SDHV | For a model of indoor unit within each basic model, an SDHV "tested combination." Additional representations are allowed, as described in paragraph (c)(3)(iii) of this section. | |
Outdoor Unit with no Match | Every model of outdoor unit distributed in commerce (tested with a model of coil-only indoor unit as specified in paragraph (b)(2)(i) of this section). |
Table 2 to Paragraph (b)(2)(i)
Category | Equipment subcategory | Must test: | With: |
Single-Package Unit | Single-Package AC (including Space-Constrained) Single-Package HP (including Space-Constrained) | The individual model with the lowest seasonal energy efficiency ratio (SEER) (when testing in accordance with appendix M to subpart B of 10 CFR part 430) or SEER2 (when testing in accordance with appendix M1 to subpart B of 10 CFR part 430) | N/A. |
Outdoor Unit and Indoor Unit (Distributed in Commerce by OUM) | Single-Split-System AC with Single-Stage or Two-Stage Compressor (including Space-Constrained and Small-Duct, High Velocity Systems (SDHV)) | The model of outdoor unit | A model of coil-only indoor unit. |
Single-Split-System HP with Single-Stage or Two-Stage Compressor (including Space-Constrained and SDHV) | The model of outdoor unit | A model of indoor unit. | |
Single-Split System AC or HP with Other Than Single-Stage or Two-Stage Compressor having a non-communicating coil-only individual combination (including Space-Constrained and SDHV) | The model of outdoor unit | A model of non-communicating coil-only indoor unit. | |
Single-Split System AC or HP with Other Than Single-Stage or Two-Stage Compressor without a non-communicating coil-only individual combination (including Space-Constrained and SDHV) | The model of outdoor unit | A model of indoor unit. | |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-non-SDHV (including Space-Constrained) | The model of outdoor unit | At a minimum, a "tested combination" composed entirely of non-ducted indoor units. For any models of outdoor units also sold with models of ducted indoor units, test a second "tested combination" composed entirely of ducted indoor units (in addition to the non-ducted combination). If testing under appendix M1 to subpart B of 10 CFR part 430, the ducted "tested combination" must comprise the highest static variety of ducted indoor unit distributed in commerce (i.e., conventional, mid-static, or low-static). | |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-SDHV | The model of outdoor unit | A "tested combination" composed entirely of SDHV indoor units. | |
Indoor Unit Only (Distributed in Commerce by ICM) | Single-Split-System Air Conditioner (including Space-Constrained and SDHV) | A model of indoor unit | The least efficient model of outdoor unit with which it will be paired where the least efficient model of outdoor unit is the model of outdoor unit in the lowest SEER combination (when testing under appendix M to subpart B of 10 CFR part 430) or SEER2 combination (when testing under appendix M1 to subpart B of 10 CFR part 430) as certified by the OUM. If there are multiple models of outdoor unit with the same lowest SEER (when testing under appendix M to subpart B of 10 CFR part 430) or SEER2 (when testing under appendix M1 to subpart B of 10 CFR part 430) represented value, the ICM may select one for testing purposes. |
Single-Split-System Heat Pump (including Space-Constrained and SDHV) | Nothing, as long as an equivalent air conditioner basic model has been tested If an equivalent air conditioner basic model has not been tested, must test a model of indoor unit | ||
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-SDHV | A model of indoor unit | A "tested combination" composed entirely of SDHV indoor units, where the outdoor unit is the least efficient model of outdoor unit with which the SDHV indoor unit will be paired. The least efficient model of outdoor unit is the model of outdoor unit in the lowest SEER combination (when testing under appendix M to subpart B of 10 CFR part 430) or SEER2 combination (when testing under appendix M1 to subpart B of 10 CFR part 430 ) as certified by the OUM. If there are multiple models of outdoor unit with the same lowest SEER represented value (when testing under appendix M to subpart B of 10 CFR part 430) or SEER2 represented value (when testing under appendix M1 to subpart B of 10 CFR part 430), the ICM may select one for testing purposes. | |
Outdoor Unit with No Match | The model of outdoor unit | A model of coil-only indoor unit meeting the requirements of section 2.2e of appendix M or M1 to subpart B of 10 CFR part 430 . |
and,
x is the sample mean; n is the number of samples; and xi is the ith sample; Or,
And x - is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.90 is the Student's t-Distribution Values for a 90 percent one-tailed confidence interval with n-1 degrees of freedom (from appendix A to this subpart). Round represented values of off-mode power consumption to the nearest watt.
and, x is the sample mean; n is the number of samples; and xi is the ith sample; or,
And x - is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.90 is the Student's t-Distribution Values for a 90 percent one-tailed confidence interval with n-1 degrees of freedom (from appendix A to this subpart). Round represented values of EER, SEER, HSPF, EER2, SEER2, and HSPF2 to the nearest 0.05.
and, x is the sample mean; n is the number of samples; and xi is the ith sample; or,
And x - is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.90 is the Student's t-Distribution Values for a 90 percent one-tailed confidence interval with n-1 degrees of freedom (from appendix A to this subpart).
Equipment type | Basic model number | Individual model number(s) | ||
1 | 2 | 3 | ||
Single-Package (including Space-Constrained) | Number unique to the basic model | Package | N/A | N/A. |
Single-Split System (including Space-Constrained and SDHV) | Number unique to the basic model | Outdoor Unit | Indoor Unit | If applicable-Air Mover (could be same as indoor unit if fan is part of indoor unit model number). |
Multi-Split, Multi-Circuit, and Multi-Head Mini-Split System (including Space-Constrained and SDHV) | Number unique to the basic model | Outdoor Unit | When certifying a basic model based on tested combination(s): * * * When certifying an individual combination: Indoor Unit(s) | If applicable-When certifying a basic model based on tested combination(s): * * *. When certifying an individual combination: Air Mover(s). |
Outdoor Unit with No Match | Number unique to the basic model | Outdoor Unit | N/A | N/A. |
10 C.F.R. §429.16