ARKANSAS SCHOOL FACILITY MANUAL PROGRAM OF REQUIREMENTS (POR) SUMMARY AND REQUIRED SPACES
SUITABILITY ANALYSIS
ARKANSAS SCHOOL FACILITY MANUAL
PROGRAM OF REQUIREMENTS
SCHOOL SUPPORT SPACES (NOT REQUIRED)
ARKANSAS SCHOOL FACILITY MANUAL
PROGRAM OF REQUIREMENTS CAREER EDUCATION (Required for 9-12)
ARKANSAS SCHOOL FACILITY MANUAL
PROGRAM OF REQUIREMENTS
REQUIRED SPACES NOTES
REQUIRED SPACES | |||
STANDARD SIZE | |||
Space | Square Feet | Notes | |
ACADEMIC CORE | |||
E-AC-3 | Kindergarten Classroom | 1000 | Maximum class size 20 students |
E-AC-4 | Kindergarten Restroom | 45 | One per kindergarten classroom |
E-AC-5a | Elem Classroom Grades 1-3 | 850 | Maximum class size 25 students |
E-AC-5b | Elem Classroom Grades 4-5 | 850 | Maximum class size 28 students |
M-AC-1a | MS Classroom Grade 6 | 850 | Maximum class size 28 students. |
M-AC-1b | MS Classroom Grades 7-8 | 850 | Maximum class size 30 students. |
M-CE-1 | Workforce Development | 1,300 | Two required for 700 or more students. |
H-AC-1 | HS Classroom | 850 | Maximum class size 30 students. |
H-AC-2 | Science Clrm/Lab-Gen/Physics | 1,440 | Minimum one plus one per each 500 students |
H-AC-3 | Science Clrm/Lab-Chemistry | 1,440 | One per each 500 students above 1,000 students. |
H-AC-4 | Science Clrm/Lab-Biol/Life Sci | 1,440 | One minimum to 1000 students. Additional for each 500 above 1000 students. |
H-AC-5 | Science Prep | 300 | |
H-AC-11 | Chemical Storage | 150 | One miminum. Two above 1500 students. |
H-AC-12 | Multi-Use Room | 1,500 | |
H-AC-13 | Instructional Multi-Purpose Rm | 850 | |
H-AC-8 | Project Lab/Classroom | 1,100 | One minimum to 1000 students. Additional for each 500 above 1000 students. |
E-MC-1 | Reading Room/Circulation | Computed | 10% of the student capacity multiplied by 35 SF per student. |
E-MC-4 | Computer Lab | 900 | |
M/H-MC-1 | Reading Room/Circulation | Computed | 10% of the student capacity multiplied by 40 SF per student. |
M-MC-4 | Media Center Computer Lab | 900 | |
E-VA-1 | Art Room | 1200 | Required for 550 or more students. |
E-VA-3 | Art Material Storage | 80 | Required for 550 or more students. |
E-AC-10 | Fine Arts Instruction Room | 1,200 | Substituted for Art and Music Room in ES with less than 550 students |
E-AC-11 | Fine Arts Instruction Storage | 100 | Substituted for Art and Music Storage in ES with less than 550 students |
M-VA-1 | Art Room | 1200 | |
H-VA-1 | Art Room | 1200 | Minimum one, plus one for each 500 students |
M/H-VA-3 | Art Material Storage | 100 | |
E-MU-1 | Music Room | 1,200 | Required for 550 or more students. |
E-MU-2 | Music Storage | 100 | Required for 550 or more students. |
M-MU-2 | Music Storage | 100 | Required for 550 or more students. |
M/H-MU-1 | Instrumental Room | 1,400 | Minimum one plus additional room for more than 1000 students. |
H-MU-2 | Instrument Storage | Computed | Minimum 200 SF. One-half SF per student. |
M-MU-8 | Vocal Room | 1,200 | Required for 700 or more students |
H-MU-8 | Vocal Room | 1,200 | Minimum one for 500 students plus additional room for more than 2000 students. |
H-MU-9 | Vocal Storage | 150 | One per vocal room. |
E-PE-1 | PE Area | Computed | 10 SF per student. Minimum 2,500 SF, Maximum 10,000 SF. Minimum single space size 900 SF. |
M-PE-1 | PE Area | Computed | 15 SF per student. Minimum 4,000 SF, Maximum 10,000 SF. Minimum single space size 900 SF. |
H-PE-1 | PE Area | Computed | 15 SF per student. Min 6,000 SF, Max 30,000 SF. Includes aux gym above 1000 students. Minimum 900 SF. |
H-PE-3 | Student Locker Room | Computed | Minimum 2 @ 400 SF. Maximum 6 @ 850 SF. |
H-PE-4 | Student Restroom/Shower | Computed | Minimum 2 @ 150 SF. Maximum 6 @ 350 SF. |
H-CE | Career Education Program One | Varies | Total. Minimum 8,000 SF. Maximum 23,000 SF. 15 SF/student. |
H-CE | Career Education Program Two | Varies | |
H-CE | Career Education Program Three | Varies | |
SPECIAL EDUCATION | |||
E/M/H-SE-1 | Self-contained Classroom | 850 | Two required for 1,000 students and above. |
E/M/H-SE-2 | Workroom/Conference | 150 | Two required for 1,000 students and above. |
E/M/H-SE-3 | Restroom/Shower | 100 | Two required for 1,000 students and above. |
E/M/H-SE-4 | Special Education/Resource | 450 | Two required for 1,000 students and above. |
E/M/H-SE-5 | Speech Therapy | 475 | Two required for 1,000 students and above. |
E/M/H-SE-7 | OT/PT | 350 | Two required for 1,000 students and above. |
E-GT-1 | Gifted and Talented | 850 | |
ADMINISTRATIVE SPACES | |||
E/M/H-AD-3 | Principal's Office | 150 | |
E/M/H-AD-4 | Assistant Principal's Office | 120 | Required for 500 or more students. |
E/M/H-AD-11 | Guidance Counselor's Office | 120 | Minimum 1. Must maintain ratio of 1:450 |
E/M/H-AD-15 | Health Center | 250 | |
PERFORMING ARTS | |||
H-PA-1 | Auditorium | Computed | Minimum 1500 SF. 5 SF per 9-12 student. |
H-PA-3 | Stage Area (includes wings) | Computed | Minimum 600 SF. 2 SF per 9-12 student. |
STUDENT DINING | |||
E/M/H-SD-1 | Student Dining | Computed | One-half of the student capacity multiplied by 15 SF per student. |
FOOD SERVICE | Only one of the two kitchens is to be used - either E-FS-1 or E-FS-2 - not both. | ||
E/M/H-FS-1 | Warming Kitchen | Computed | 2 SF per student. |
E/M/H-FS-2 | Kitchen (total) | Computed | Equal to sum of areas for preparation, serving, dry food storage, cooler/freezer, and ware washing. |
E/M/H-FS-2a | Preparation Area | Computed | Student capacity multiplied by 3.5 SF per student multiplied by 36%. |
E/M/H-FS-2b | Serving Area | Computed | Student capacity multiplied by 3.5 SF per student multiplied by 34%. |
E/M/H-FS-2c | Dry Food Storage | Computed | Student capacity multiplied by 3.5 SF per student multiplied by 11%. |
E/M/H-FS-2d | Cooler/Freezer | Computed | Student capacity multiplied by 3.5 SF per student multiplied by 10%. |
E/M/H-FS-2e | Ware Washing | Computed | Student capacity multiplied by 3.5 SF per student multiplied by 9%. |
BUILDING SERVICES | |||
E/M/H-CU-1 | Workroom | Computed | 0.5 SF per student. Minimum 125 SF. |
E/M/H-MultiSt | Vertical Circulation | Computed | Vertical Circulation for Multi-Story Schools |
E/M/H-BS-1 | Large Group Restrooms | Computed | Equal to the sum of the program areas, excluding building services, multiplied by 3%. |
E/M/H-BS-2 | Custodial Closet | 50 | |
E/M/H-BS-3 | Electrical Closet | 50 | |
E/M/H-BS-4 | Telecommunications Room | 64 | |
E/M/H-BS-5 | Corridors/Circulation | Computed | Equal to the sum of the program areas, excluding building services, multiplied by 20%. |
E/M/H-BS-6 | Mech/Elect Space/Decks | Computed | Equal to the sum of the program areas, excluding building services, multiplied by 5.5%. |
E/M/H-BS-7 | Storage Area | 150 | |
E/M/H-BS-8 | Central Storage Area | 150 | |
E/M/H-BS-9 | Loading/Receiving Area | 100 | |
E/M/H-BS-10 | Main Cross-connect | 150 |