N.J. Stat. § 45:5A-54

Current through L. 2024, c. 87.
Section 45:5A-54 - Requirements of perimeter fence intrusion protection system

A perimeter fence intrusion protection system shall:

a. interface with a monitored alarm device in a manner that enables the burglar alarm system to transmit a signal intended to summon the business or law enforcement, or both, in response to an intrusion or burglary;
b. be located on property that is not designated by a municipality exclusively for residential use;
c. have an energizer that is driven by a commercial storage battery that is not more than 12 volts of direct current;
d. have an energizer that meets the standards set forth by the International Electrotechnical Commission Standard 60335-2-76, in its current edition, and as amended and supplemented;
e. be surrounded by a nonelectric perimeter fence or wall that is not less than five feet in height;
f. not exceed ten feet in height or two feet higher than the nonelectric perimeter fence or wall described in subsection e. of this section, whichever is higher;
g. be marked with conspicuous warning signs that are located on the perimeter fence intrusion protection system at not more than 40 foot intervals and that read: "WARNING-ELECTRIC FENCE";
h. comply with the requirements set forth in the rules and regulations adopted by the board; and
i. be installed by a person trained by the manufacturer or certified in the installation, maintenance, repair, safety and operation of the perimeter fence intrusion protection system.

N.J.S. § 45:5A-54

Added by L. 2021, c. 2,s. 2, eff. 1/21/2021.