Section 45:5A-54 - Requirements of perimeter fence intrusion protection systemA perimeter fence intrusion protection system shall:
a. interface with a monitored alarm device in a manner that enables the burglar alarm system to transmit a signal intended to summon the business or law enforcement, or both, in response to an intrusion or burglary;b. be located on property that is not designated by a municipality exclusively for residential use;c. have an energizer that is driven by a commercial storage battery that is not more than 12 volts of direct current;d. have an energizer that meets the standards set forth by the International Electrotechnical Commission Standard 60335-2-76, in its current edition, and as amended and supplemented;e. be surrounded by a nonelectric perimeter fence or wall that is not less than five feet in height;f. not exceed ten feet in height or two feet higher than the nonelectric perimeter fence or wall described in subsection e. of this section, whichever is higher;g. be marked with conspicuous warning signs that are located on the perimeter fence intrusion protection system at not more than 40 foot intervals and that read: "WARNING-ELECTRIC FENCE";h. comply with the requirements set forth in the rules and regulations adopted by the board; andi. be installed by a person trained by the manufacturer or certified in the installation, maintenance, repair, safety and operation of the perimeter fence intrusion protection system.Added by L. 2021, c. 2,s. 2, eff. 1/21/2021.