225 ILCS 705/11.10

Current through Public Act 103-1052
Section 225 ILCS 705/11.10 - Materials For Barricade

Each working section of a mine must have an emergency sled or wagon located no more than 1,000 feet from the working faces of the mine with the following materials and amounts in constant supply:

(1) 8 timbers of suitable length or roof jacks of equal capability;
(2) 200 linear feet of brattice cloth of adequate height to the coal seam;
(3) 2 hand saws;
(4) 20 1 x 6 brattice boards at least 12 feet long each;
(5) 10 pounds of 10d nails;
(6) 10 pounds of 16d nails;
(7) 10 pounds of spads;
(8) 25 cap boards;
(9) 20 header boards;
(10) 2 axes;
(11) 2 claw hammers;
(12) one sledge hammer;
(13) one shovel;
(14) 10 bags of wood fiber plaster or 5 bags of cement or the equivalent;
(15) 4 sets of rubber gloves; and
(16) 5 gallons of sealed, distilled drinking water.

225 ILCS 705/11.10

Added by P.A. 094-1041, § 5, eff. 7/24/2006.