(a) A dead-line anchor for a hoisting line (wire rope) shall be so constructed, installed and maintained that its strength shall at least equal the working strength of the hoisting line.
(b) Every hoisting line (wire rope) used in servicing operations shall have a minimum safety factor of three (3), determined as follows:
Safety B (Nominal breaking point of the wire rope in pounds) Factor W (Calculated total static load in pounds)
- (i) A minimum safety factor of two (2) shall be permitted only in the following operations:
- (A) On rotary drilling line when setting casing; or
- (B) When pulling on stuck pipe and similar infrequent operations.
(c) All hoisting lines (wire rope) shall be visually inspected by a competent person of the servicing rig daily and shall be thoroughly inspected at least each 30 days. Any wire rope shall be removed from service when any of the following conditions exist:
(d) The wire rope (wire line) manufacturer's recommendations shall be utilized.
(e) On any drum on which a hoisting line (wire rope) is wound, the end of the hoisting line (wire rope) shall be fastened securely to the drum.
(f) The hoisting line (wire rope) shall not be removed from the drum until:
(g) The hoisting line (wire rope) shall not be in direct contact with any derrick member, any stationary equipment or material in the derrick, except the crown block and any traveling block sheaves, a line spooler, a line stabilizer, weight indicator or dead line anchor.
(h) Every overhead sheave or pulley which a line spooler counterweight rope runs shall be fastened securely to its support.
(i) Chains.
(j) Winches and cables.
(k) Chain used in connection with servicing or production operations shall be suitable for the type of service.
(l) Any chain shall be discarded or repaired if it has been stretched to the point where links bind, kink, lock or it has been broken.
(m) Fiber ropes cut, frayed (through one or more lays) or that have been in contact with caustic acid, or any other chemical that might weaken them, shall be replaced immediately.
(n) Cable clamps shall be installed according to the chart in the Rigger's Handbook.
053-6 Wyo. Code R. § 6-2