(a) Welding, cutting and brazing within seventy-five (75) feet of well bore shall require a written hot work permit in accordance with Chapter 6 section 8, (c) (iv).
(b) Proper protective hoods and glasses shall be worn by the welder.
(c) Fire extinguishers shall be provided for welding operations as required by Chapter 3, Section 4. b.(xi) of these rules and regulations.
(d) Compressed gas cylinders shall be stored in a well-protected, well-ventilated, dry location, at least twenty (20) feet from combustible materials. Cylinders shall be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures, such as lockers and cupboards.
(e) Oxygen cylinders, and all attachments thereto, shall be kept free of all grease and oil and other hydrocarbons.
053-5 Wyo. Code R. § 5-2