(a) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person.
(b) Only one face in a working place shall be blasted at a time, except that when blasting cut coal up to three faces may be blasted in a round if each face has a separate kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit to fire more than 20 boreholes in a round under the provisions of 30 CFR 75.1320 and 75.1321 may not be obtained for use when blasting multiple faces.
(c) Before blasting--
(d) All shots shall be fired promptly, after all persons have been removed to a safe location.
053-4 Wyo. Code R. § 75.1325