053-3 Wyo. Code R. § 57.22207

Current through April 27, 2019
Section 57.22207 - Booster fans (I-A, II-A, III, and V-A mines)

(a) Booster fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18, and be-

  • (1) Provided with an automatic signal device located so that it can be seen or heard by a person designated by the mine operator to give an alarm when the fan stops or when methane reaches the following levels:
    • (i) 1.0 percent at the fan in Subcategory I-A, Category III, and Subcategory V-A mines; and
    • (ii) 0.5 percent at the fan in Subcategory II-A mines.
  • (2) Equipped with a device that automatically deenergizes power in affected workings should the fan stop; and
  • (3) Equipped with starting and stopping controls located at the fan and at another accessible remote location.

(b) Booster fan installations, except for booster fans installed in ducts, shall be-

  • (1) Provided with doors which open automatically when all fans in the installation stop; and
  • (2) Provided with an air lock when passage through the fan bulkhead is necessary.

053-3 Wyo. Code R. § 57.22207