(a) An ignition interlock service provider shall: - (i) Service a device within 30 days after the initial installation and thereafter as recommended by the manufacturer, but not to exceed 60 days.
- (ii) Ensure that another device is substituted whenever an installer removes a device for any reason.
- (iii) Calibrate every installed device at least every 60 days.
(b) At each service visit, the ignition interlock service provider shall: - (i) Perform a calibration confirmation test to verify that the device measures an approved reference sample within plus or minus 0.005 grams per 210 liters of the known concentration of the reference sample.
- (A) If the result of the calibration confirmation test is not within plus or minus 0.005 grams per 210 liters of the known concentration of the approved reference sample, the service center operator shall recalibrate the device.
- (B) If the device fails the calibration confirmation test after being recalibrated, the service center operator shall ensure that a new device is installed.
- (ii) Check that the device will permit a driver to restart a vehicle within 5 minutes without taking another breath test after the vehicle has stalled or been turned off.
- (iii) Check the device for evidence of tampering and circumvention. An ignition interlock service provider shall document and photograph any perforations, cuts, or other evidence of possible tampering.
045-10 Wyo. Code R. § 10-9