010-4 Wyo. Code R. § 4-2

Current through April 27, 2019
Section 4-2 - Conveying Sewage

(a) Filter backwash water and water drained from a pool, spa or similar installation shall be discharged into a sanitary sewer through an approved air gap or disposed of by other means approved of by the regulatory authority.

(b) There shall be no direct physical connection between the wastewater disposal system and a drain or re-circulation system.

(c) Backwash water or water drained from a pool, spa or similar installation shall:

  • (i) Be discharged through an air gap formed by positioning the discharge pipe opening at least two (2) pipe diameters above the overflow level of any confining barrier which could cause flooding and submergence of the discharge opening, in the event that the disposal system should fail or by other means approved by the regulatory authority.
    • (A) Splash screening barriers are permitted as long as they do not destroy air gap effectiveness.

010-4 Wyo. Code R. § 4-2