Wis. Admin. Code Department of Natural Resources NR 283.21

Current through October 28, 2024
Section NR 283.21 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available
(1) Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the effluent limitations representing the degree of effluent reduction attainable by the application of BPT, which is calculated by multiplying the average process water usage flow rate for the cleaning water processes at a point source times the following pollutant concentrations:

Table 2

Cleaning Water

Concentration used to calculate effluent limitations

Pollutant or pollutant property

Maximum for any 1 day (mg/l)

Maximum for monthly average

BOD5

49

22

Oil and grease

71

17

TSS

117

36

pH

(1)

(1)

1 Within the range of 6.0 to 9.0 at all times.

(2) The department shall obtain the average process water usage flow rate for the cleaning water processes from the permittee.

Wis. Admin. Code Department of Natural Resources NR 283.21

Cr. Register, October, 1987, No. 382, eff. 11-1-87.