Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by application of BPT:
Table 194
Batch Alkaline Cleaning
BPT Effluent Limitations | ||
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Pollutant or pollutant property | kg/kkg (pounds per 1,000 pounds) of product | |
TSS | 0.0730 | 0.0313 |
O&G | 0.0313 | 0.0104 |
pH | (1) | (1) |
(1) Within the range of 6.0 to 9.0
Table 195
Continuous Alkaline Cleaning
BPT Effluent Limitations | ||
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Pollutant or pollutant property | kg/kkg (pounds per 1,000 pounds) of product | |
TSS | 0.102 | 0.0438 |
O&G | 0.0438 | 0.0146 |
pH | (1) | (1) |
(1) Within the range of 6.0 to 9.0
Wis. Admin. Code Department of Natural Resources NR 254.112