Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by application of BPT:
Table 45
Copper Sulfate, Copper Chloride, Copper Iodide, and Copper Nitrate
BPT Effluent Limitations | ||
kg/kkg (pounds per 1,000 pounds) of copper salts | ||
Pollutant or pollutant property | Maximum for any 1 day | Average of daily values for 30 consecutive days |
TSS | 0.069 | 0.023 |
Copper | 0.0030 | 0.0010 |
Nickel | 0.0060 | 0.0020 |
Selenium | 0.0015 | 0.00050 |
pH | (1) | (1) |
(1) Within the range of 6.0 to 9.0
Table 46
Copper Carbonate
BPT Effluent Limitations | ||
kg/kkg (pounds per 1,000 pounds) of copper salts | ||
Pollutant or pollutant property | Maximum for any 1 day | Average of daily values for 30 consecutive days |
TSS | 4.2 | 1.4 |
Copper | 0.19 | 0.064 |
Nickel | 0.37 | 0.12 |
Selenium | 0.093 | 0.031 |
pH | (1) | (1) |
(1) Within the range of 6.0 to 9.0
Wis. Admin. Code Department of Natural Resources NR 230.362