Wis. Admin. Code Department of Natural Resources NR 667.0202

Current through August 26, 2024
Section NR 667.0202 - What special requirements shall I meet for ignitable or reactive wastes?
(1) You may not place ignitable or reactive waste in tank systems, unless:
(a) You treat, render, or mix the waste before or immediately after placement in the tank system so that:
1. You comply with s. NR 667.0017(2).
2. The resulting waste, mixture or dissolved material no longer meets the definition of ignitable or reactive waste under s. NR 661.0021 or 661.0023.
(b) You store or treat the waste in such a way that it is protected from any material or conditions that may cause the waste to ignite or react.
(c) You use the tank system solely for emergencies.
(2) If you store or treat ignitable or reactive waste in a tank, comply with the requirements for the maintenance of protective distances between the waste management area and any public ways, streets, alleys or an adjoining property line that can be built upon as required in Tables 2-1 to 2-6 of the National Fire Protection Association's "Flammable and Combustible Liquids Code," (1977 or 1981), as incorporated by reference in s. NR 660.11.

Wis. Admin. Code Department of Natural Resources NR 667.0202

Adopted by, CR 16-007: cr. Register July 2017 No. 739, eff.8/1/2017
Amended by, CR 19-082: am. (1) (a) 2. Register August 2020 No. 776, eff. 9/1/2020