Wis. Admin. Code Department of Natural Resources NR 665.0444

Current through October 28, 2024
Section NR 665.0444 - Inspections
(1) During construction or installation, liners, and cover systems (for example, membranes, sheets, or coatings) shall be inspected for uniformity, damage, and imperfections (for example, holes, cracks, thin spots, or foreign materials). Immediately after construction or installation, liners shall be inspected and certified as meeting the requirements of s. NR 665.0443 by a qualified professional engineer. The certification shall be maintained at the facility as part of the facility operating record. After installation, liners, and covers shall be inspected to ensure tight seams and joints and the absence of tears, punctures, or blisters.
(2) While a drip pad is in operation, it shall be inspected weekly and after storms to detect evidence of any of the following:
(a) Deterioration, malfunctions or improper operation of run-on and run-off control systems.
(b) The presence of leakage in and proper functioning of the leakage detection system.
(c) Deterioration or cracking of the drip pad surface.

Wis. Admin. Code Department of Natural Resources NR 665.0444

CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
Amended by, CR 16-007: am. (1) Register July 2017 No. 739, eff.8/1/2017

See s. NR 665.0443(13) for remedial action required if deterioration or leakage is detected.