Note: Copies of 40 CFR Part 132, Appendix A Sections II, IV and V are available for inspection in the offices of the department of natural resources, secretary of state and the legislative reference bureau, Madison, WI or may be purchased from the superintendent of documents, US government printing office, Washington, D.C. 20402.
EW = sum of the 4 squares of the ln GMAVs,
EP = sum of the 4 P values,
EPR = sum of the 4 square roots of P, and
JR = square root of 0.05.
EW = sum of the 4 squares of the ln GMAIs,
EP = sum of the 4 P values,
EPR = sum of the 4 square roots of P, and
JR = square root of 0.05.
ATC = e(V ln(water quality parameter) + ln ACI).
The ATE shall be applicable only over the range of water quality parameters equivalent to the mean plus or minus 2 standard deviations using the entire fresh water acute toxicity data base and the water quality parameter transformation employed in par. (a). If the value at a specific location is outside of that range, the endpoint of the range nearest to that value shall be used to determine the criterion. Additional information may be used to modify those ranges. The final acute value (FAV) equals 2 times the ATC (acute toxicity criterion) calculated using the formula in this paragraph.
WQCD = (CF)(WQCTotal R.)
Where: WQCTotal R. = Criteria from NR 105, Table 1 or 2.
CF = Conversion factor for total recover- able to dissolved.
Conversion factors are as follows:
Arsenic | 1.000 |
Cadmium | 0.850 |
Chromium (III) | 0.316 |
Chromium (VI) | 0.982 |
Copper | 0.960 |
Lead | 0.875 |
Mercury | 0.850 |
Nickel | 0.998 |
Selenium | 0.922 |
Silver | 0.850 |
Zinc | 0.978 |
WQCTRAN = (Translator)(WQCD)
Where: Translator (unitless) = ((MP)(TSS) + MD)/MD
MP = Particle-bound concentration of the pollutant (ug/g) in receiving water.
MD = Dissolved concentration of the pollutant in receiving water (ug/L).
TSS = Total Suspended Solids (g/L) concentration in receiving water.
Wis. Admin. Code Department of Natural Resources NR 105.05