Note: An example of parameters other than coating consumption and mass solids content for estimating the relative mass of coating solids used would be design specifications for the parts or products coated and the number of items produced.
where:
Facility-specific emission limit is the facility-specific emission limit for each 12-month compliance period, kg (lb) of organic HAP per kg (lb) of coating solids used
Limiti is the new source or existing source emission limit applicable to coating operation, i, included in the facility-specific emission limit, converted to kg (lb) of organic HAP per kg (lb) of coating solids used, if the emission limit is not already in those units. All emission limits included in the facility-specific emission limit shall be in the same units.
Solidsi is the kg (lb) of solids used in coating operation, i, in the 12-month compliance period that is subject to emission limit, i. You may estimate the mass of coating solids used from parameters other than coating consumption and mass solids content. The use of parameters other than coating consumption and mass solids content shall be approved by the administrator.
n is the number of different coating operations included in the facility-specific emission limit
Note: An example of parameters other than coating consumption and mass solids content for estimating the relative mass of coating solids used would be design specifications for the parts or products coated and the number of items produced.
Wis. Admin. Code Department of Natural Resources NR 465.33