Table 1
VOC content Limits for Solvents and Solvent Solutions Used in Industrial Cleaning Operations
Cleaning Activity | VOC Content of Solvent or Solvent Solution in kilograms per liter (pounds per gallon) |
1. Product cleaning or surface preparation during manufacturing process | 0.05 (0.42) |
2. Repair cleaning or maintenance cleaning | 0.05 (0.42) |
3. Cleaning of coatings (excluding adhesives) application equipment | |
a. General | 0.05 (0.42) |
b. Heptane-containing end sealant application equipment lines | 0.70 (5.8) |
4. Cleaning of ink application equipment | |
a. General | 0.05 (0.42) |
b. Metal can identification ink application equipment | 0.89 (7.4) |
Table 1A
VOC Composite Partial Vapor
Pressure for Solvents and Solvent Solutions Used in Industrial Cleaning Operations
Cleaning Activity | VOC Composite Partial Vapor Pressure for Solvents and Solvent Solutions in mm of Hg at 20°C |
1. Product cleaning or surface preparation during manufacturing process | 8.0 |
2. Repair cleaning or maintenance cleaning | 8.0 |
3. Cleaning of coatings (excluding adhesives) application equipment | |
a. General | 8.0 |
b. Heptane-containing end sealant application equipment lines | 10.0 |
4. Cleaning of ink application equipment | 8.0 |
Wis. Admin. Code Department of Natural Resources NR 422.05