Table 45-21F. Coefficients of the total resource effectiveness (TRE)index equation | ||||||
A1. For chlorinated process vent streams, if 0 [LESS THAN EQUAL TO] net heating value (MJ/scm) [LESS THAN EQUAL TO] 3.5: | ||||||
FL = vent stream flow rate (scm/min) | a | b | c | d | e | f |
FL [LESS THAN EQUAL TO] 13.5 | 48.73 | 0 | 0.404 | -0.1632 | 0 | 0 |
13.5 < FL [LESS THAN EQUAL TO] 700 | 42.35 | 0.624 | 0.404 | -0.1632 | 0 | 0.0245 |
700 < FL [LESS THAN EQUAL TO] 1,400 | 84.38 | 0.678 | 0.404 | -0.1632 | 0 | 0.0346 |
1,400 < FL[LESS THAN EQUAL TO] 2,100 | 126.41 | 0.712 | 0.404 | -0.1632 | 0 | 0.0424 |
2,100 < FL [LESS THAN EQUAL TO] 2,800 | 168.44 | 0.747 | 0.404 | -0.1632 | 0 | 0.0490 |
2,800 < FL [LESS THAN EQUAL TO] 3,500 | 210.47 | 0.758 | 0.404 | -0.1632 | 0 | 0.0548 |
A2. For chlorinated process vent streams, if 3.5 < net heating value (MJ/scm): | ||||||
FL = vent stream flow rate (scm/min) | a | b | c | d | e | f |
FL [LESS THAN EQUAL TO] 13.5 | 47.76 | 0 | -0.292 | 0 | 0 | 0 |
13.5 < FL [LESS THAN EQUAL TO] 700 | 41.58 | 0.605 | -0.292 | 0 | 0 | 0.0245 |
700 < FL [LESS THAN EQUAL TO] 1,400 | 82.84 | 0.658 | -0.292 | 0 | 0 | 0.0346 |
1,400 < FL [LESS THAN EQUAL TO] 2,100 | 123.10 | 0.691 | -0.292 | 0 | 0 | 0.0424 |
2,100 < FL [LESS THAN EQUAL TO] 2,800 | 165.36 | 0.715 | -0.292 | 0 | 0 | 0.0490 |
2,800 < FL [LESS THAN EQUAL TO] 3,500 | 206.62 | 0.734 | -0.292 | 0 | 0 | 0.0548 |
B. For nonchlorinated process vent streams, if 0 [LESS THAN EQUAL TO] net heating value (MJ/scm) [LESS THAN EQUAL TO] 0.48: | ||||||
FL = vent stream flow rate (scm/min) | a | b | c | d | e | f |
FL [LESS THAN EQUAL TO] 13.5 | 19.05 | 0 | 0.113 | -0.214 | 0 | 0 |
13.5 < FL [LESS THAN EQUAL TO] 1,350 | 16.61 | 0.239 | 0.113 | -0.214 | 0 | 0.0245 |
1,350 < FL [LESS THAN EQUAL TO] 2,700 | 32.91 | 0.260 | 0.113 | -0.214 | 0 | 0.0346 |
2,700 < FL [LESS THAN EQUAL TO] 3,500 | 49.21 | 0.273 | 0.113 | -0.214 | 0 | 0.0424 |
C. For nonchlorinated process vent streams, if 0.48 < net hearing value (MJ/scm) [LESS THAN EQUAL TO] 1.9: | ||||||
FL = vent stream flow rate (scm/min) | a | b | c | d | e | f |
FL [LESS THAN EQUAL TO] 13.5 | 19.74 | 0 | 0.400 | -0.202 | 0 | 0 |
13.5 < FL [LESS THAN EQUAL TO] 1,350 | 18.30 | 0.138 | 0.400 | -0.202 | 0 | 0.0245 |
1,350 < FL [LESS THAN EQUAL TO] 2,700 | 36.28 | 0.150 | 0.400 | -0.202 | 0 | 0.0346 |
2,700 < FL [LESS THAN EQUAL TO] 4,050 | 54.26 | 0.158 | 0.400 | -0.202 | 0 | 0.0424 |
D. For nonchlorinated process vent streams, if 1.9 < net heating value (MJ/scm) [LESS THAN EQUAL TO] 3.6: | ||||||
FL = vent stream flow rate (scm/min) | a | b | c | d | e | f |
FL [LESS THAN EQUAL TO] 13.5 | 15.24 | 0 | 0.033 | 0 | 0 | 0 |
13.5 < FL [LESS THAN EQUAL TO] 1,190 | 13.63 | 0.157 | 0.033 | 0 | 0 | 0.0245 |
1,190 < FL [LESS THAN EQUAL TO] 2,380 | 26.95 | 0.171 | 0.033 | 0 | 0 | 0.0346 |
2,380 < FL [LESS THAN EQUAL TO] 3,570 | 40.27 | 0.179 | 0.033 | 0 | 0 | 0.0424 |
E. For nonchlorinated process vent streams, if 3.6 < net heating value (MJ/scm): | ||||||
FL = vent stream flow rate (scm/min) | a | b | c | d | e | f |
FL [LESS THAN EQUAL TO] 13.5 | 15.24 | 0 | 0 | 0.0090 | 0 | 0 |
13.5 < FL [LESS THAN EQUAL TO] 1,190 | 13.63 | 0 | 0 | 0.0090 | 0.0503 | 0.0245 |
1,190 < FL [LESS THAN EQUAL TO] 2,380 | 26.95 | 0 | 0 | 0.0090 | 0.0546 | 0.0346 |
2,380 < FL [LESS THAN EQUAL TO] 3,570 | 40.27 | 0 | 0 | 0.0090 | 0.0573 | 0.0424 |
1 Mention of trade names or specific products does not constitute endorsement by the Secretary.
W. Va. Code R. § 45-21-50