Emission limits that apply to small, remote incinerators after February 7, 2018a
Air pollutant | Emission limitb | Averaging timec | Performance test methodsc |
Cadmium | 0.95 milligrams per dry standard cubic meter. | 3-run average (collect a minimum volume of 1 dry standard cubic meter). | Performance test (Method 29 of 40CFR 60, appendix A-8). |
Carbon monoxide | 64 parts per million dry volume. | 3-run average (1-hour minimum sample time per run). | Performance test (Method 10 at 40CFR 60, appendix A-4). |
Dioxins/furans (total mass basis) | 4400 nanograms per dry standard cubic meter. | 3-run average (collect a minimum volume of 1 dry standard cubic meter). | Performance test (Method 23 at 40CFR 60, appendix A-7). |
Dioxins/furans (toxic equivalency basis) | 180 nanograms per dry standard cubic meter. | 3-run average (collect a minimum volume of 1 dry standard cubic meter). | Performance test (Method 23 of 40CFR 60, appendix A-7). |
Fugitive ash | Visible emissions for no more than 5% of the hourly observation period. | Three 1-hour observation periods. | Visible emission test (Method 22 at 40CFR 60, appendix A-7). |
Hydrogen chloride | 300 parts per million dry volume. | 3-run average (For Method 26, collect a minimum volume of 120 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run). | Performance test (Method 26 or 26A at 40CFR 60, appendix A-8). |
Lead | 2.1 milligrams per dry standard cubic meter. | 3-run average (collect a minimum volume of 1 dry standard cubic meter). | Performance test (Method 29 of 40CFR 60, appendix A-8). Use ICPMS for the analytical finish. |
Mercury | 0.0053 milligrams per dry standard cubic meter. | 3-run average (For Method 29 and ASTM D6784-02 (Reapproved 2008), collect a minimum volume of 2 dry standard cubic meters per run. For Method 30B, collect a minimum sample as specified in Method 30B at 40CFR 60, appendix A). | Performance test (Method 29 or 30B at 40CFR 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008). |
Nitrogen oxides | 190 parts per million by dry volume. | 3-run average (for Method 7E, 1-hour minimum sample time per run). | Performance test (Method 7 or 7E of 40CFR 60, appendix A-4). |
Particulate matter (filterable) | 270 milligrams per dry standard cubic meter. | 3-run average (collect a minimum volume of 1 dry standard cubic meter). | Performance test (Method 5 or 29 at 40CFR 60, appendix A-3 or appendix A-8). |
Sulfur dioxide | 150 parts per million dry volume. | 3-run average (for Method 6, collect a minimum of 20 liters per run; for Method 6C, 1-hour minimum sample time per run). | Performance test (Method 6 or 6C of 40CFR 60, appendix A-4). |
aThe date specified in the state plan can be no later than 3 years after the effective date of approval of a revised state plan or February 7, 2018.
bAll emission limitations (except for opacity) are measured at 7 percent oxygen, dry basis at standard conditions. For dioxins/furans, the owner or operator shall meet either the total mass basis limit or the toxic equivalency basis limit.
cIn lieu of performance testing, the owner or operator may use a CEMS or, for mercury, an integrated sorbent trap monitoring system, to demonstrate initial and continuing compliance with an emissions limit, as long as the owner or operator complies with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in 9.9.a through 9.9.z and 9.10.a through 9.10.5. As prescribed in 9.9.u, if the owner or operator uses a CEMS or integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, the averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.
W. Va. Code R. agency 45, tit. 45, ser. 45-18, tbl. 45-18M