Emissions limits for small, medium, and large HMIWI at designated facilities as set forth in 45CSR §§ 18-7.2.a.1 and 7.2.a.2.

Pollutant

Units

(7 percent oxygen, dry basis)

Emissions Limits

Averaging Time1

Compliance Method2

HMIWI Size

Small

Medium

Large

Particulate matter

Milligrams per dry standard cubic meter (mg/dscm) (grains per dry standard cubic foot (gr/dscf))

66 (0.029)

46 (0.020)

25 (0.011)

3-run average (1-hour minimum sample time per run)

EPA Reference Method 5 of appendix A-3 of 40CFR 60, or EPA Reference Method 26A or 29 of appendix A-8 of 40CFR 60.

Carbon monoxide

Parts per million by volume (ppmv)

20

5.5

11

3-run average (1-hour minimum sample time per run)

EPA Reference Method 10 or 10B of appendix A-4 of 40CFR 60.

Dioxins/furans

Nanograms per dry standard cubic meter total dioxins/furans (ng/dscm) (grains per billion dry standard cubic feet (gr/109dscf)) or ng/dscm TEQ (gr/109dscf)

16 (7.0)

or 0.013 (0.0057)

0.85 (0.37)

or 0.020 (0.0087)

9.3 (4.1)

or 0.054

(0.024)

3-run average (4-hour minimum sample time per run)

EPA Reference Method 23 of appendix A-7 of 40CFR 60.

Hydrogen chloride

ppmv

44

7.7

6.6

3-run average (1-hour minimum sample time per run)

EPA Reference Method 26 or 26A of appendix A-8 of 40CFR 60.

Sulfur dioxide

ppmv

4.2

4.2

9.0

3-run average (1-hour minimum sample time per run)

EPA Reference Method 6 or 6C of appendix A-4 of 40CFR 60.

Nitrogen oxides

ppmv

190

190

140

3-run average (1-hour minimum sample time per run)

EPA Reference Method 7 or 7E of appendix A-4 of 40CFR 60.

Lead

mg/dscm (grains per thousand dry standard cubic feet (gr/103dscf))

0.31 (0.14)

0.018 (0.0079)

0.036

(0.016)

3-run average (1-hour minimum sample time per run)

EPA Reference Method 29 of appendix A-8 of 40CFR 60.

Cadmium

mg/dscm (gr/103dscf)

0.017 (0.0074)

0.013 (0.0057)

0.0092 (0.0040)

3-run average (1-hour minimum sample time per run)

EPA Reference Method 29 of appendix A-8 of 40CFR 60.

Mercury

mg/dscm (gr/103dscf)

0.014 (0.0061)

0.025

(0.011)

0.018 (0.0079)

3-run average (1-hour minimum sample time per run)

EPA Reference Method 29 of appendix A-8 of 40CFR 60.

1Except as allowed under 40 CFR § 60.56c(c) for HMIWI equipped with CEMS.

2Does not include CEMS and approved alternative non-EPA test methods allowed under 40 CFR § 60.56c(b).

W. Va. Code R. agency 45, tit. 45, ser. 45-18, tbl. 45-18B