2.01. Dust shall not accumulate on roof of tipples and buildings to an excess that would endanger workmen.
2.02. Dust shall be controlled by the use of permissible dust collectors, water or other approved methods, within practicable limits.
2.03. Belt conveyors shall be equipped with side boards or other protective devices, where necessary, to protect persons from from falling material.
2.04. Ladders shall be securely fastened.
2.05. Ramps shall be provided with securely anchored rubbing boards of ample dimensions.
2.06 A dumping block at least 8 inches high shall be installed at all dumping points, excluding stockpiles.
2.07 Lights shall be provided as needed in or around surface structures.
2.08 Electrical wiring in tipples and buildings shall be done in a safe and workman-like manner.
2.09 Persons working over or -in open bins or silos shall use a safety harness.
2.10. Each open bin or silo shall be equipped with an inside ladder.