Wash. Admin. Code § 51-54A-1004

Current through Register Vol. 24-23, December 1, 2024
Section 51-54A-1004 - Occupant load

1004.5 Areas without fixed seating. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in Table 1004.5. For areas without fixed seating, the occupant load shall be not less than that number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space as set forth in Table 1004.5. Where an intended function is not listed in Table 1004.5, the fire code official shall establish a function based on a listed function that most nearly resembles the intended function.

EXCEPTION:

Where approved by the fire code official, the actual number of occupants for whom each occupied space, floor, or building is designed, although less than those determined by calculation, shall be permitted to be used in the determination of the design occupant load.

1004.5.1 Increased occupant load. The occupant load permitted in any building, or portion thereof, is permitted to be increased from that number established for the occupancies in Table 1004.5, provided that all other requirements of the code are met based on such modified number and the occupant load does not exceed one occupant per 7 square feet (0.65 m2) of occupiable floor space. Where required by the fire code official, an approved aisle, seating or fixed equipment diagram substantiating any increase in occupant load shall be submitted. Where required by the fire code official, such diagram shall be posted.

Table 1004.5

Maximum Floor Area Allowances Per Occupant

Function of Space

Occupant Load Factora

Accessory storage areas, mechanical equipment room

300 gross

Agricultural building

300 gross

Aircraft hangars

500 gross

Airport terminal

Baggage claim

Baggage handling

Concourse

Waiting areas

20 gross

300 gross

100 gross

15 gross

Assembly

Gaming floors (keno,slots, etc.)

Exhibit gallery and museum

Billiard table/game table area

11 gross

30 net

50 gross

Assembly with fixed seats

See Section 1004.6

Assembly without fixed seats

Concentrated (chairs only - Not fixed)

Standing space

Unconcentrated (tables and chairs)

7 net

5 net

15 net

Bowling centers, allow 5 persons for each lane including 15 feet of runway and for additional areas

7 net

Business areas

Concentrated business use areas

150 gross

See Section 1004.8

Courtrooms - Other than fixed seating areas

40 net

Day care

35 net

Dormitories

50 gross

Educational

Classroom area

Shops and other vocational room areas

20 net

50 net

Exercise rooms

50 gross

Fixed guideway transit and passenger rail systems

Platform

Concourse/lobby

100 gross (See Section 4901)

Group H-5 fabrication and manufacturing areas

200 gross

Industrial areas

100 gross

Institutional areas

Inpatient treatment areas

Outpatient areas

Sleeping areas

240 gross

100 gross

120 gross

Kitchens, commercial

200 gross

Library

Reading rooms

Stack area

50 net

100 gross

Locker rooms

50 gross

Mall buildings - Covered and open

See Section 402.8.2 of the IBC

Mercantile

Storage, stock, shipping areas

60 gross

300 gross

Parking garages

200 gross

Residential

200 gross

Skating rinks, swimming pools

Rink and pool

Decks

50 gross

15 gross

Stages and platforms

15 net

Warehouses

500 gross

For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 m2

a Floor area in square feet per occupant.

Wash. Admin. Code § 51-54A-1004

Adopted by WSR 22-13-093, Filed 6/14/2022, effective 7/1/2023