Wash. Admin. Code § 448-16-060

Current through Register Vol. 24-21, November 1, 2024
Section 448-16-060 - Determining agreement of duplicate breath samples

Pursuant to RCW 46.61.506 the following method is approved for determining whether two breath samples agree to within plus or minus 10 percent of their mean.

(1) The breath test results will be reported, truncated to three decimal places.
(2) For the Data Master instruments, the mean of the two breath test results will be calculated and rounded to four decimal places. For the Drager instrument, the mean of all four results will be calculated and truncated to four decimal places.
(3) The lower acceptable limit will be determined by multiplying the above mean by 0.9, and truncating to three decimal places.
(4) The upper acceptable limit will be determined by multiplying the mean by 1.1 and truncating to three decimal places.
(5) If the individual results fall within and inclusive of the upper and lower acceptable limits, the two breath samples are valid.

Wash. Admin. Code § 448-16-060

Amended by WSR 22-21-032, Filed 10/6/2022, effective 11/6/2022

Statutory Authority: RCW 46.61.506. 10-24-066, § 448-16-060, filed 11/30/10, effective 12/31/10; 04-19-144, § 448-16-060, filed 9/22/04, effective 10/23/04.