Section 296-863-40055 - Meet these additional requirements when operating liquefied petroleum gas (LPG) fueled PITs
(1) You must make sure you do not park PITs near:
(a) Sources of heat, open flames, or similar ignition sources; or
(b) Open pits, such as service pits, that do not have adequate ventilation.
(2) You must make sure PITs stored inside a garage do not have:
(a) A leak in the fuel system;
(b) Fuel containers filled beyond the maximum filling capacity.

Reference: See WAC 296-24-47505(12), Storage and handling of liquefied petroleum gases, for maximum filling capacities.