Exemption: | Periodic employee exposure monitoring is not required if exposure monitoring results conducted to fulfill requirements in Exposure evaluation, WAC 296-855-20050, are below the action level (AL). |
You must obtain employee exposure monitoring results according to the frequency specified in Table 2, Periodic Exposure Evaluation Frequencies.
Note: | * If you documented that one work shift consistently has higher exposure monitoring results than another for a particular operation, then you may limit sample collection to the work shift with higher exposures and use those results to represent all employees performing the operation on other shifts. |
Table 2 Periodic Exposure Evaluation Frequencies
If employee exposure monitoring results: | Then: |
Are between the: * Action level (AL) of 0.5 parts per million (ppm); AND | Conduct additional exposure monitoring at least every 6 months. |
* TWAg of 1 ppm | |
Are above the TWA8; OR Above the STEL | Conduct additional exposure monitoring at least every 3 months. |
Have been obtained at least every 3 months; AND Have 2 consecutive monitoring results, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the TWA8, but remain at or above the AL | You may decrease your evaluation frequency for the TWA8 to every 6 months. |
Have 2 consecutive evaluations, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the AL and STEL | You may stop periodic exposure evaluations. |
Wash. Admin. Code § 296-855-30010
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-17-168, § 296-855-30010, filed 8/23/05, effective 1/1/06.