Section 296-835-11025 - Periodically inspect your dip tanks and associated equipment and correct any deficiencies(1) You must inspect or test your dip tanks and associated equipment periodically, including: (c) Bottom drains and valves;(d) Electrical wiring, equipment, and grounding connections;(f) Fire extinguishing equipment.(2) You must inspect the hoods and ductwork of the ventilation system for corrosion and damage and make sure the airflow is adequate:(a) At least quarterly during operation;(b) Prior to operation after a prolonged shutdown.(3) You must promptly fix any deficiencies found. Note: | 1. To assist you in tracking your inspections and actions taken from those inspections, you may want to keep a written record. |
| 2. It is recommended that inspections be at least quarterly even if the system is not operating. Depending on the chemicals in use more frequent inspection may be required. |