Wash. Admin. Code § 296-835-13015

Current through Register Vol. 24-23, December 1, 2024
Section 296-835-13015 - Meet specific requirements if you use a flow coating process
(1) You must make sure all piping is substantial and rigidly supported.
(2) You must make sure the paint is supplied by a:
(a) Gravity tank that does not hold more than ten gallons (38 L); or
(b) Direct low-pressure pumping system.
(3) You must have an approved heat-actuated device that shuts down the pumping system if there is a fire.

Note:

The area of the sump, and any areas on which paint flows, should be included in the area of dip tank.

Wash. Admin. Code § 296-835-13015

Amended by WSR 17-18-075, Filed 9/5/2017, effective 10/6/2017

Statutory Authority: RCW 49.17.010, [49.17].040, and[49.17].050 . 02-15-102, § 296-835-13015, filed 7/17/02, effective 10/1/02.