Processes and work operations that use formaldehyde in these manners will probably require further investigation at the worksite to determine the extent of employee monitoring that should be conducted.
Mg/m3=(A)(B)/C.
where A=ug/mL from 3.7.2, B=desorption volume, and C=L of air sampled.
No desorption efficiency corrections are required.
ppm=(mg/m3)(24.45)/MW
where mg/m3=result from 3.7.3, 24.45=molar volume of an ideal gas at 760 mm Hg and 25 5151C, MW=molecular weight (Formaldehyde=30.0).
The coated adsorbent is now ready to be packed into sampling tubes. The sampling tubes should be stored in a sealed container to prevent contamination. Sampling tubes should be stored in the dark at room temperature. The sampling tubes should be segregated by coated adsorbent lot number. A sufficient amount of each lot number of coated adsorbent should be retained to prepare analytical standards for use with air samples from that lot number.
Wash. Admin. Code § 296-62-07544
Statutory Authority: Chapter 49.17 RCW. 91-11-070 (Order 91-01), § 296-62-07544, filed 5/20/91, effective 6/20/91; 90-03-029 (Order 89-20), § 296-62-07544, filed 1/11/90, effective 2/26/90; 89-11-035 (Order 89-03), § 296-62-07544, filed 5/15/89, effective 6/30/89; 88-21-002 (Order 88-23), § 296-62-07544, filed 10/6/88, effective 11/7/88.