IMPORTANT:
See WAC 296-307-624 Scope, for:
The employer must select and provide, at no cost to employees, appropriate respirators for routine use, infrequent use, and reasonably foreseeable emergencies (such as escape, emergency, and spill response situations) by completing the following process:
Respirator Selection Process
Step 1: If the only respirator use is for escape, skip to Step 8 to select appropriate respirators.
Step 2: If the respiratory hazard is a biological aerosol, such as TB (tuberculosis), anthrax, psittacosis (parrot fever), or hanta virus, select a respirator appropriate for nonemergency activities recognized to present a health risk to workers AND skip to Step 8.
Step 3: If the respiratory hazard is a pesticide, follow the respirator specification on the pesticide label AND skip to Step 9.
Step 4: Determine the expected exposure concentration for each respiratory hazard of concern. Use the results from the evaluation required by WAC 296-307-624, Respiratory hazards.
Step 5: Determine if the respiratory hazard is classified as IDLH; if it is NOT IDLH skip to Step 7.
The respiratory hazard IS classified as IDLH if:
OR
OR
Notes: | 1. WISHA uses the IDLH values in the 1990 edition of the NIOSH Pocket Guide to Hazardous Chemicals to determine the existence of IDLH conditions. The employer may use more recent editions of this guide. Visit www.cdc.gov/niosh for more information. 2. If your measured or estimated expected exposure concentration is below NIOSH's IDLH values, proceed to Step 7. |
Step 6: Select an appropriate respirator from one of the following respirators for IDLH conditions and skip to Step 8:
OR
Exception: | If the respiratory hazard is oxygen deficiency AND the employer can show oxygen concentrations can be controlled within the ranges listed in Table 4 under ALL foreseeable conditions, the employer is allowed to select ANY type of SCBA or airline respirator. |
Table 4 Concentration Ranges for Oxygen Deficiency
Altitude(as ft. above sea level) | Oxygen Concentration Range(as percent oxygen) |
Below 3,001 | 16.0 - 19.5 |
3,001 - 4,000 | 16.4 - 19.5 |
4,001 - 5,000 | 17.1 - 19.5 |
5,001 - 6,000 | 17.8 - 19.5 |
6,001 - 8,000 | 19.3 - 19.5 |
Above 8,000 feet the exception does not apply. |
Step 7: Identify respirator types with assigned protection factors (APFs) from Table 5 that are appropriate to protect employees from the expected exposure concentration.
Step 8: Consider hazards that could require selection of specific respirator types. For example, select full-facepiece respirators to prevent eye irritation or abrasive blasting helmets to provide particle rebound protection.
Step 9: Evaluate user and workplace factors that might compromise respirator performance, reliability or safety.
If the respiratory hazard is a pesticide, follow the requirements on the pesticide label and skip to Step 11.
Examples:
Step 10: Follow Table 6 requirements to select an air-purifying respirator.
If Table 6 requirements cannot be met, the employer must select an air-line respirator or an SCBA.
Step 11: Make sure respirators the employer selects are certified by the National Institute for Occupational Safety and Health (NIOSH).
To maintain certification, make sure the respirator is used according to cautions and limitations specified on the NIOSH approval label.
Note: | While selecting respirators, the employer will need to select a sufficient number of types, models or sizes to provide for fit testing. The employer can also consider other respirator use issues, such as accommodating facial hair with a loose fitting respirator. |
Use Table 5 to identify the assigned protection factor for different types of respirators.
Table 5 Assigned Protection Factors (APF) for Respirator Types
If the respirator is a(n)... | Then the APF is... |
Air-purifying respirator with a: | |
* Half-facepiece............. | 10 |
* Full-facepiece............. | 100 |
Note: Half-facepiece includes 1/4 masks, filtering facepieces, and elastomeric facepieces. | |
Powered air-purifying respirator (PAPR) with a: | |
* Loose-fitting facepiece...... | 25 |
* Half-facepiece............. | 50 |
* Full-facepiece, equipped with HEPA filters, chemical cartridges or canisters................. | 1000 |
* Hood or helmet, equipped with HEPA filters, chemical cartridges or canisters................. | 1000 |
Air-line respirator with a: | |
* Half-facepiece and designed to operate in demand mode...... | 10 |
* Loose-fitting facepiece and designed to operate in continuous flow mode................. | 25 |
* Half-facepiece and designed to operate in continuous-flow, or pressure-demand mode....... | 50 |
* Full-facepiece and designed to operate in demand mode...... | 100 |
* Full-facepiece and designed to operate in continuous-flow OR pressure-demand mode....... | 1000 |
Helmet or hood and designed to operate in continuous-flow mode | 1000 |
Self-contained breathing apparatus (SCBA) with a tight fitting: | |
* Half-facepiece and designed to operate in demand mode...... | 10 |
* Full-facepiece and designed to operate in demand mode...... | 100 |
* Full-facepiece and designed to operate in pressure-demand mode..................... | 10,000 |
Combination respirators: | |
* Find the APF for each type of respirator in the combination. | The lowest value |
* Use the lower APF to represent the combination. |
Use Table 6 to select air-purifying respirators for particle, vapor, or gas contaminants.
Table 6 Requirements for Selecting Any Air-purifying Respirator
If the contaminant is a.. . | Then... |
* Gas OR vapor | *Provide a respirator with canisters or cartridges equipped with a NIOSH-certified, end-of-service-life indicator (ESLI) OR *If a canister or cartridge with an ESLI is NOT available, develop a cartridge change schedule to make sure the canisters or cartridges are replaced before they are no longer effective OR *Select an atmosphere-supplying respirator |
* Particle, such as a dust, spray, mist, fog, fume, or aerosol | * Select respirators with filters certified to be at least 95% efficient by NIOSH - For example, N95s, R99s, P100s, or High Efficiency Particulate Air filters (HEPA) OR * The employer may select respirators NIOSH certified as "dust and mist," "dust, fume, or mist," OR "pesticides." The employer can only use these respirators if particles primarily have a mass median aerodynamic diameter of at least two micrometers. Note: These respirators are no longer sold for occupational use. |
Wash. Admin. Code § 296-307-60205