Mechanical local exhaust ventilation may be provided by either of the following:
Welding zone | Minimum air flow cubic feet/minutes | Duct diameter inches |
4 to 6 inches from arc or torch | 150 | 3 |
6 to 8 inches from arc or torch | 275 | 3-1/2 |
8 to 10 inches from arc or torch | 425 | 4-1/2 |
10 to 12 inches from arc or torch | 600 | 5-1/2 |
Wash. Admin. Code § 296-307-50015
97-09-013, recodified as § 296-307-50015, filed 4/7/97, effective 4/7/97. Statutory Authority: RCW 49.17.040,[49.17.]050 and [49.17.]060. 96-22-048, § 296-306A-50015, filed 10/31/96, effective 12/1/96.